NewAge Products 66992 Guide D'installation Et D'utilisation page 28

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Instructions for Installer (Licensed Gas Fitter)
Gas Line Purging
You should purge the gas line of air before attempting to light the grill.
Make sure all grill controls are in the "OFF" position.
Slowly turn on the main gas supply.
Open the lid for the entire purging procedure.
Push in the control knobs (do not turn) for the Sear Burner and the Main Burner on the furthest
right for about 20 seconds to allow the air in the system to purge. These are furthest from
the fuel source and will completely purge the lines. Release the control knobs. Wait at least 5
minutes after releasing the control before attempting to light the burners. (applicable with 40"
Grill 2.0 only).
Gas Hook-Up Instructions
BUILT IN PROPANE GAS HOOK-UP: The piping up to the gas grill is the responsibility of the installer
and piping should be located as shown in the built-in instructions. Do not use a hose to connect the
unit except to connect the cylinder regulator to the piping system. It must be connected with rigid
pipe, copper tube or an approved flexible metal connector which complies with ANSI Z21.24/ CSA
6.10 or ANSI Z21.75/CSA 6.27.
The installation must comply with CAN B149.1 Natural Gas and Propane installation code in Canada,
or to the National Fuel Gas code, ANSI Z223.1 in the United States. The gas supply pipe must be
sufficiently sized to supply the BTU/h specified on the rating plate, based on the length of the
piping run. If installing a side burner, a separate line must be branched off to the side burner unit
and enter the side burner opening at the specified location. If the enclosure is to house a propane
cylinder, the tank portion of the enclosure must be ventilated according to local codes, and must
not have communication with the cavity used to enclose the gas grill. A propane cylinder can not be
stored below the gas grill.
BUILT IN CYLINDER ENCLOSURES: Built in cylinder enclosures which completely enclose the
cylinder must have both of the following:
1. At least one unobstructed ventilation opening on the exposed exterior side of the enclosure
located within 5 in (127mm) of the top of the enclosure. The opening must have a total free area
of more than 20 in2 (130 cm2) for a 20 lb (9.1 kg) cylinder.
2. At least one ventilation opening on the exposed, exterior side of the enclosure located 1 in (25.4
mm) or less from the floor level. The opening must have a total free area of more than 20 in2 (130
cm2) for a 20 lb(9.1 kg) cylinder. The upper edge must be no more than 5 in (127 mm) above the
floor level.
Every opening must be large enough to permit the entrance of a 1/8 in (3.2 mm) rod.
28

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

66282

Table des Matières