Never connect a gas line directly to the grill. A pressure regulator must be installed on all gas
equipment. Removing or failing to install the pressure regulator can result in fire, and serious
personal injury and will void the warranty. This grill is designed for non-combustible enclosures
only, and must be installed and serviced by a licensed gas fitter to local codes.
As indicated on the rating plate, this gas grill is designed to operate with gas supply pressures
of 11" WC for Propane. For installations where the gas supply pressure exceeds these
requirements, a regulator must be installed upstream of the grill's components. If the gas supply
pressure is lower than these requirements, the unit will be under-fired and will not reach the
maximum temperatures. Ensure that the supply line size complies with local and/or national
installation codes.
The grill is factory set to use Propane. It is critical that the gas you use matches that which the grill
was set up for. You can verify that by checking the rating plate.
CLASS NO / CATÉGORIE #: 2711 04/84
WARNING:
NEWAGE PERFORMANCE 40" GRILL
APPLIANCE IS NOT IN USE. IF THESE INSTRUCTIONS ARE NOT FOLLOWED
PROPANE GAS
EXACTLY, A FIRE CAUSING DEATH OR SERIOUS INJURY MAY OCCUR.
OUTDOOR COOKING APPLIANCE- FOR OUTDOOR USE ONLY. IF STORED INDOORS, DETACH
1 3/4"/32 MM
AND LEAVE CYLINDER OUTDOORS. DO NOT USE THIS APPLIANCE UNDER OVERHEAD
ATTENTION:
COMBUSTABLE SURFACES. ONLY FOR INSTALLATION IN A BUILT-IN ENCLOSURE
CONSTRUCTED OF NON-COMBUSTIONABLE MATERIALS. / APPAREIL DE CUISINE DE PLEIN
BOUTEILLE SI L'APPAREIL N'EST PAS UTILISÉ. SI CES INSTRUCTIONS NE SONT
AIR- POUR UTILISATION À L'EXTÉRIEUR SEULEMENT. SI L'APPAREIL EST ENTREPOSÉ À
PAS SUIVIES EXACTEMENT, UN INCENDIE CAUSE LA MORT OU DES BLESSURES
L'INTÉRIEUR, ENLEVER LES BOUTEILLES ET LES LAISSER À L'EXTÉRIEUR. NE PAS UTILISER CET
GRAVES PEUVENT SURVENIR.
APPAREIL SOUS UNE SURFACE COMBUSTIBLE. CONVIENT UNIQUEMENT POUR INSTALLA-
TION DANS UNE ENCEINTE ENCASTRÉE FAITE DE MATÉRIAUX INCOMBUSTIBLES.
Rating Plate - Lists model numbers and gas type
Water Column Requirements
Fuel
PROPANE
11 in wc (LPG)
The rating plate is located in one or more of the following places:
On the back of Grill
Ensure that the gas supplied meets with the minimum pressure requirements. Do not operate the
grill on any gas other than that for which the grill has been set.
Both the regulator and the manifold orifices have been tuned for the type of gas specified on the
rating plate.
All installation and all installation parts must conform to local codes with the National Electrical
Code, ANSI Z223.1/ NFPA 70 latest edition and the National Fuel Gas Code, ANS Z223.1/NFPA 54
in the U.S. and CGA-B149.1/.2 in Canada. Canadian installations must conform to CGA-B149.1/.2
natural gas/propane installation code. (Canada)
CAUTION:
THIS APPLIANCE IS ADJUSTED AND SHIPPED FOR USE WITH PROPANE GAS. USE ONLY
TURN OFF PROPANE GAS SUPPLY AT CYLINDER WHEN
THE GAS PRESSURE REGULATOR SUPPLIED WITH THIS APPLIANCE. THIS REGULATOR IS SET FOR AN OUTLET
PRESSURE OF 11" in WC (2.739 kPa). IF THE GAS SUPPLY PRESSURE IS LOWER THAN THESE REQUIREMENTS,
THE UNIT WILL BE UNDER-FIRED AND WILL NOT REACH THE MAXIMUM TEMPERATURES. ENSURE THAT THE
SUPPLY LINE SIZE COMPLIES WITH LOCAL AND/OR NATIONAL INSTALLATION CODES.
AVERTISSEMENT:
COUPER L'ALIMENTATION EN GAZ PROPANE À LA
CET APPAREIL EST RÉGLÉ ET EXPÉDIÉ POUR UTILISATION AVEC DU GAZ
PROPANE. UTILISER UNIQUEMENT LE REGULATEUR DE PRESSION DE GAZ FOURNI AVEC CET APPAREIL. CE
REGULATEUREST REGLE POUR UNE PRESSION DE SORTIE DE 11 POUCES DE COLONNE D"EAU (2.739 kPa). SI
L'ALIMENTATION DE GAZ LA PRESSION EST INFÉRIEURE À CES EXIGENCES, L'UNITÉ SERA SOUS-CUIT ET
N'ATTAQUE PAS LES TEMPÉRATURES MAXIMALES. ASSUREZ-VOUS QUE LA TAILLE DE LA LIGNE
D'ALIMENTATION EST CONFORME AUX CODES D'INSTALLATION NATIONAUX.
WC Min Under
Full Load
WARNING
MODEL/ MODÈLE
3 X 12,000 BTU/ MAIN TUBE BURNERS / BRÛLEURS À
TUBES PRINCIPAUX
PERFORMANCE 40" GRILL LP
X
66992
1 X 12,000 BTU/ IR SEAR BURNER/BRÛLEUR SAISIR
INFRAROUGE À HAUTE TEMPÉRATURE
PERFORMANCE 40" GRILL LP
66282
WITH 40" GRILL CART
ORIFICE SIZES/ GRANDEUR DES ORIFICS
PROPANE
EQUIPPED FOR USE WITH
MAIN BURNERS/ BRÛLEUR PRINCIPAL
1.03MM
PROPANE
IR SEAR BURNER/BRÛLEUR SAISIR
1.03MM
INFRAROUGE À HAUTE TEMPÉRATURE
23 "/ 584.2 MM
MINIMUM CLEARENCE FROM SIDES AND BACK OF UNIT TO
GRILL PULSE IGNITOR REQUIREMENTS:
COMBUSTIBLE CONSTRUCTION, 14 INCHES FROM SIDES, AND 18
INPUT- AA BATTERY
INCHES FROM BACK. ONLY FOR INSTALLATION IN A BUILT-IN
(Rechargeable and Non-Rechargeable)
ENCLOSURE CONSTRUCTED OF NON-COMBUSTIONABLE MATERIALS
OR NEWAGE GRILL CABINETS. SEE MODELS.
MFG DATE DE FABRICATION :
DÉGAGEMENT MINIMAL ENTRE LES PAROIS LATÉRALES ET L'ARRIÈRE
DE L'APPAREIL ET LA CONSTRUCTION COMBUSTIBLE, 14 POUCES À
PARTIR DES PAROIS LATÉRALES ET 18 POUCES À PARTIR DE
L'ARRIÈRE. UNIQUEMENT POUR L'INSTALLATION DANS UN BOÎTIER
INTÉGRÉ CONSTRUIT DE MATÉRIAUX NON COMBUSTIBLES OU POUR
APPAREIL DE GRILLE ET D'ARMOIRES NEWAGE.
Supplier to APPLY
PRODUCTION CODE STICKER
111 CREDITVIEW ROAD, 2nd FLOOR
L4L-9T1
C
US
ANS Z21.58-2018•CSA 1.6-2018
Class IIIA-2
Outdoor Cooking Gas Appliances
27

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

66282

Table des Matières