6.3. Directions for Mounting

The unit should be mounted in
frost-free rooms only.
The unit can be mounted on
a wall or on a separate frame
which may be installed in pro-
duction areas and anchored to
the floor.
For mounting on walls, please
note the following:
The wall for mounting should
be either a stable brick wall or
a wall made of concrete.
The delivered bracket should be
secured to the wall by the en-
closed screws and correspond-
ing dowels
The wall bracket should be
mounted on the wall according
to the above description and the
unit is hung on to the bracket.
The hose and Product holders
should be mounted afterwards.
(See Installation/Mounting)

6.4. Transportation

For secure transportation of the unit, we
recommend always to ensure, that the
unit can not slide or tip. The unit might
have to be secured with straps.
Transportation of the unit only in horison-
tal position: The unit must not be placed
on the front where you find the operation
panel. Neither can it be placed on top or
bottom where connections and outlets
are mounted.
In case the unit is moved at a tempera-
ture of approx or below 0°C (32°F), you
must always make sure that the the unit
has been fully emptied for water. If this is
not the case, you may damage the unit.

6.5. Vibrations

Hand-arm vibrations according to ISO
5349-1.

6.6. Water Connection

Before the unit is connected to
the water supply pipe, the supply
line should be rinsed carefully
in order to remove coarse
impurities and metal shavings.
The connection for water must
be made at the top of the unit.
(see layout drawing)
Minimum internal diameter of the
supply pipe must be at least ½"
external (ø16 mm internal).
The pressure loss in the supply
line must be held as low as
possible by
avoiding long supply pipes
mounting low pressure
resistance ball valves and
avoiding fittings with high
pressure loss.
When installing the piping, take
care to avoid air traps.
All pipe connections to the unit
must be screwed connections
ensuring simple maintenance
and dismantling of the station.
Max. allowed temperature
of supplied water:
Max. allowed pressure
of supplied water:
Water consumption
at rinsing mode:
For an optimum functioning of the
injector system, we recommend
installing a filter on the inlet to avoid
impurities
Water inlet
70°C
6 bar
12 l/min