IMPORTANT INSTRUCTIONS -
:
Models
AS50, AS60, AS70
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
electric shock and injury to person, including the following:
1. Read all instructions before installing or using exhaust fan.
2. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer.
3. Before servicing or cleaning the unit, switch power off at
service panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When
the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the
service panel.
4. Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes
and standards, including fire-related construction.
5. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent back drafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA)
and the American Society for Heating, Refrigeration, and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
CAUTION:
FOR GENERAL VENTILATING USE ONLY. DO
NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS
AND VAPORS.
210572050 Rev. B 11-05
OPERATING MANUAL
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
SAVE THESE INSTRUCTIONS
6. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
7. Ducted fans must always be vented to the outdoors.
8. This unit must be grounded.
9. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off
power unit.
WARNING:
DO NOT USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL
DEVICE.
10. Acceptable for use over a bathtub or shower when installed
in a GFCI protected branch circuit.
11. NEVER place a switch where it can be reached from a tub or
shower.
WARNING:
www.airkinglimited.com
Exhaust Fan
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
DO NOT USE IN KITCHENS
1 of 8

Publicité

Table des Matières
loading

Sommaire des Matières pour AirKing AS50

  • Page 1 IMPORTANT INSTRUCTIONS - OPERATING MANUAL Models Exhaust Fan AS50, AS60, AS70 READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2 INSTALLATION INSTRUCTIONS SECTION 3 Existing Construction CAUTION: MAKE SURE POWER IS SWITCHED OFF AT 1. Position housing against the joist or stud and trace an outline SERVICE PANEL BEFORE STARTING INSTALLATION. of the housing onto the ceiling/wall material (Figure 4). Set SECTION 1 housing aside and cut opening, being careful not to cut or damage any electrical or other hidden utilities.
  • Page 3: Troubleshooting Guide

    2. From where you have access to inside the fan’s junction 2. Install the grill by squeezing the two ends of the springs box, connect the White wire from the house to the White together and installing them up into the slots of the fan’s wire from the fan’s receptacle.
  • Page 4 5S1999002 14 ga Ground Wire 5S1999003 Goose Neck Wire Cover 5S1201004 #8 Screw 5S1999004 AS Motor Plate 5S1201005 Captive Screw 5S1999005 Motor - AS50 5S2201001 Motor - AS60 5S2201002 Motor - AS70 5S2201003 Hex Nut 5S1999006 Impeller 5S1299001 Scroll 5S1201006...
  • Page 5: Instructions Importantes - Manuel D'opération

    MANUEL D’OPÉRATION Modéles Ventilateur d’Évacuation AS50, AS60, AS70 LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 6: Préparation Du Ventilateur D'évacuation

    INSTRUCTIONS D’INSTALLATION SECTION 3 Construction Existante AVERTISSEMENT: VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER 1. Positionner le cabinet contre la solive ou le montant et tracer L’INSTALLATION. le contour du cabinet sur le matériau du mur / plafond (Figure 4).
  • Page 7: Guide De Dépannage

    1. Courir le filage d’un interrupteur mural approuvé de calibre 2. Installer la grille en pressant les deux extrémités des ressorts approprié. Un fil neutre (blanc), un fil de mise à la terre (vert ensemble et en les installant dans les fentes du venturi du ou cuivre dénudé), et un fil vivant (fil noir connecté...
  • Page 8: Garantie Limitée

    Fil de mise à la terre de calibre # 14 5S1999003 Couvre fil en col-de-cygne 5S1201004 Vis #8 5S1999004 Plaque de moteur AS 5S1201005 Vis imperdable 5S1999005 Moteur - AS50 5S2201001 Moteur - AS60 5S2201002 Moteur - AS70 5S2201003 Écrou hexagonal 5S1999006 Hélice 5S1299001...