Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

IMPORTANT INSTRUCTIONS -
Models:
AS50, AS60, AS70, AS54
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN
THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL
When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock and
WARNING:
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If you have
questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
WARNING:
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment manufacturer's guideline
and safety standards such as those published by the National Fire
Protection Association (NFPA) and the American Society for Heating,
Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
210572050 Rev. H 12-15
OPERATING MANUAL
INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
injury to person, including the following:
TO REDUCE THE RISK
TO REDUCE THE RISK
SAVE THESE INSTRUCTIONS
CAUTION:
DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE
MATERIALS AND VAPORS.
d) Ducted fans must always be vented to the outdoors.
e) This unit must be grounded.
f) To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
g) Read all instructions before installing or using exhaust fan.
a) Acceptable for use over a bathtub or shower when installed in a
GFCI protected branch circuit.
WARNING:
www.airkinglimited.com
Exhaust Fan
FOR GENERAL VENTILATING USE ONLY.
WARNING:
TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, DO NOT USE THIS FAN WITH
ANY SOLID-STATE SPEED CONTROL DEVICE.
DO NOT USE IN KITCHENS.
1 of 8

Publicité

Table des Matières
loading

Sommaire des Matières pour AirKing AS50

  • Page 1 IMPORTANT INSTRUCTIONS - OPERATING MANUAL Models: Exhaust Fan AS50, AS60, AS70, AS54 READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2 INSTALLATION INSTRUCTIONS CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. SECTION 1 Preparing the Exhaust Fan Unpack fan from the carton and confirm that all pieces are present. In addition to the exhaust fan you should have: 1 - Grill Figure 4 1 - Damper Assembly (attached)
  • Page 3: Troubleshooting Guide

    SECTION 6 SECTION 7 Completing the Installation Use and Care CAUTION: Reinstall the fan’s venturi by holding it at approximately a 45 degree angle, hook the two MAKE SURE POWER IS SWITCHED OFF AT tabs on the venturi into the slots on the housing and secure in place by tightening the SERVICE PANEL BEFORE STARTING INSTALLATION.
  • Page 4: Customer Service

    4" Plastic Collar and Damper 5S2299054 Polarized Receptacle 5S1999001 Goose Neck Wire Cover 5S1201004 AS Motor Plate 5S1201005 Motor with Impeller - AS50/AS54 5S1201026 Motor with Impeller - AS60 5S1201050 Motor with Impeller - AS70 5S1201031 Scroll 5S1201006 Grill Springs...
  • Page 5: Instructions Importantes - Manuel D'opération

    INSTRUCTIONS IMPORTANTES – MANUEL D’OPÉRATION Modèles: Ventilateur d’Évacuation AS50, AS60, AS70, AS54 LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 6: Nouvelle Construction

    INSTRUCTIONS D’INSTALLATION ATTENTION : VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER L’INSTALLATION. SECTION 1 Préparation du Ventilateur d’évacuation Sortir le ventilateur de sa boite et confirmer que toutes les pièces sont présentes. En plus du ventilateur d’évacuation vous devriez avoir: Figure 4 1 - Grille...
  • Page 7: Guide De Dépannage

    SECTION 6 SECTION 7 Complétion de l’installation Utilisation et entretien ATTENTION : Réinstaller le venturi du ventilateur en le tenant à un angle d’environ 45 degrés, VOUS ASSURER QUE L’ALIMENTATION accrocher les deux onglets sur le venturi dans les fentes sur le cabinet et fixer en EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER place en serrant les vis du venturi.
  • Page 8: Garantie Limitée

    Collet de plastique de 10,2 cm (4 po) 5S2299054 Réceptacle polarisé 5S1999001 Couvre fil en col-de-cygne 5S1201004 Plaque de moteur AS 5S1201005 Moteur avec hélice - AS50, AS54 5S1201026 Moteur avec hélice - AS60 5S1201050 Moteur avec hélice - AS70 5S1201031 Volute 5S1201006...

Ce manuel est également adapté pour:

As60As70As54