•Adjust airflow accordingly. An Actual Evaporator Exit Temperature.
below the Target Evaporator Exit Temperature. indicates low airflow.
Increasing airflow can be accomplished by eliminating restrictions in the duct system,
increasing blower speed, cleaning filters or opening registers. An Actual Evaporator Exit
Temperature. Above the Evaporator Exit Temperature. usually indicates low capacity.
Occasionally airflow is higher than expected. Look for causes of low capacity such as
refrigerant mischarge or a dirty condenser coil. If the airflow is high, correct it by lowering
the fan speed.
Note: If "OL" is displayed, then the measurements are out of range.
Retake the temperature measurements and ensure the temperature inputs are correct.
Important:
Because everything within the system is interdependent, one adjustment can affect other
parts of the system. For example, increasing airflow increases the superheat, which may
require adding refrigerant. After any modifications, allow 15 minutes to stabilize and then
retest. For the best results take measurements right after each other.
10. Select °C or °F
Turn the Meter ON by pressing the button
, Select °C or °F by pressing "C/F" button
until °C or °F is displayed in the LCD. Press and holding "C/F" button for 2s to select
backlight on or off.

11. Auto-Power-Off (APO)

• This meter shall enter a sleep mode after 15 minutes of inactivity,
• Pressing the MODE button while turning the meter from OFF to ON shall cause the APO
to be disabled, and the APO icon to be turned off.
Warning:
As battery power is not sufficient, LCD will display " ", the battery should be replaced at
this time.
7
EN
KTD-02