Connection to the basic collecting pipe
Establish a connection to the basic connection pipe
(DN100).
The cover plate also provides protection during the con-
struction period.
4.2
Deeper installation
Only use the KESSEL extension section art. no. 32500 for
deeper installation.
22 / 92
Do not fit more than one extension section in order not to
exceed the maximum installation depth.
4.3
Connecting the pipes
Drill/fit additional pipes (max. DN100) if necessary
If no ventilation takes place through the cover, a separate
ventilation pipe must be laid (via the roof).
Additional connections (additional inlets, conduit pipes,
ventilation pipes) must be made at least at the height of
the pre-drilled inlets and with a minimum distance of 10
cm between each other.
Use the KESSEL hole saw (art. no. 500101) or equivalent
to drill holes for the additional pipes.
Only push the pipes in to such an extent that functional
units (e.g. float switches) are not impaired.
Installation and operating manual
016-168