Safety
2.4
Comfort for employing and safety functioning. The electronic digital control panel order
the combined action of combusted gas fan, combustible feed, convection fan and
environment temperature control. This control system guarantee the best conditions for
combustion and functioning, reducing to the minimum the exercise cost.
The best efficiency with minimal emission. The wide surface of thermical exchange,
with the best air combustion control, has the best combustible exploitation as result.
The measured out pellet loading in the foyer allows a complete combustion with the
lower toxic values into the exhaust gas.

AUTOMATIC SAFETY FUNCTION

Voltage Fall : After a short voltage fall, the stove stop than it will start again
automatically with normal function or with the light on phase. This operation is free of
risk for safety.
Extinction for overheating : In case of stove overheating, the safety system turn off the
stove automatically. The stove should be lighted on again after a pause of 45 min for
cooling. If this situation will repeated please call the assistance service.
Extinction for low temperature : If the stove temperature go down a certain value, the
stove turn off ( for example the combustible is finished ) This extinction could happen
also when the stove don't complete the starting phase. The stove should be light on
again.
Electrical safety device for over current : The stove is protected from overcurrent,
with a fuse ( see technical data ) placed on electronic card.
For its replacement, contact Technical Service

RESIDUAL RISKS

The stove does not present itself potential risks, although it is complete with coatings in all its
parts, nevertheless the following residual risks may be present:
Risk of burns
Between the back of the stove and the smoke outlet (fume outlet pipe).
Contact with glass
Electric risk
Alimentation cable
Motors connection
Risk of fire
Opening the front door when the ashes are not extinguished.
Risk of cutting
Between the auger shaft and the material loading conduit; in the event of a jam, do not
carry out any material removal operations unless the stove has been switched off and the
power supply disconnected.