Important Warning - Lincar Monellina Manuel D'instructions Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

COMBUSTION REGULATIONS
Sometimes changing the pellets, in sight of the several types of wood pellets presents on the
market, some modifications on equipment combustion could appear. An evident signal of a
wrong combustion is the excessive or lack quantity of pellets in then burner during the normal
functioning. It's possible to make some regulations on the equipment combustion. The basket
– burner during the normal combustion should contain combustible from 1/3 till a middle of
its capacity, if necessary, to carry on to some regulations, please follows the following points :
a.
To check the equipment functioning and check if in the burner basket, the pellets
accumulate till the complete fill up of its or if the burner basket emptied till the flame
light off.
b.
Push several times the button 3(SET) to visualize on the top part of the display ut40
c.
Push several times the button 1 to visualize on the lower part of the display the num.33
d.
Push the button 3(SET), the display visualize "corr" in the top part and a number in
the lower part.
e.
Employing the button 1 and 2 to modify the number on the lower display as indicated
in the enclosed schedule, to increase the pellets quantity increase the value, to reduce
the pellets quantity reduce the value.
ATTENTION ! We recommend to make these modifications increasing/reducing the initial
value little by little ( only one number ), checking the equipment functioning for 1 or 2 days
even taking care to keep clean the basket burner, only after this checking period You can
modify again the regulation.
Increase the pellets quantity
9
8
7
6
5
STAND-BY
The STAND-BY status means that when the equipment reach the ambiance temperature set
up, the equipment turn off to start again automatically when a lower temperature is taken.
This is the procedure to follow :
Push several times the button 3(SET) to visualize on the top part of the display ut04
-
Push several times the button 1 to visualize on the lower part of the display the
-
numb.99
Push the button 3(SET), the display visualize "StAn by" in the top part and "OFF" in
-
the lower part.
Program the °C (es 1°-2° ecc) the temperature value to activate the STAND-BY
-
modality. Program OFF to deactivate the STAND-BY modality.
The stove will function in STAND-BY modality so when the temperature ambiance is
-
reached as set out °C in the preceding point : EX : it's set up 2° to preceding point and
supposing to have set the equipment to 22°C the modality STAND-BY will activate
when the 24°C is reached (22° + 2°) The equipment will light on when the ambiance
temperature will be lower than it set up, in this case 22°C.

IMPORTANT WARNING

The stove has to be cold before making every intervention, cleaning or maintenance
operation.
TO REMOVE THE PLUG ALWAYS BEFORE MAKE EVERY INTERVENTION
ON THE STOVE
During the functioning, in case of problems You can push the Stop button situated on
control panel. To not break off the functioning removing the plug or pushing the
back button because this operation block all motors, creating a very difficult exhaust
fumes evacuation.
IT IT IT IT- - - - GB
GB- - - - FR
GB
GB
4
3
2
1
0
46/108
FR- - - - ES
ES mod. 156P PLUS - 176PL PLUS 2018
FR
FR
ES
ES
Reduce the pellets quantity
-1
-2
-3
-4
-5
-6
-7
-8
-9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Birikkina176pl plus156p plus

Table des Matières