Device Information - Dimplex LIK 8TE Instructions D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

12

12 Device Information

1
Type and order code
2
Design
2.1
Model
2.2
Degree of protection according to EN 60 529 for compact devices
and heating components
2.3
Installation location
3
Performance data
3.1
Operating temperature limits:
Heating water flow/return flow
Air
3.2
Temperature spread of heating water (flow/return flow) at A7 / W35
3.3
Heat output / COP
3.4
Sound power level device / outdoors
3.5
Sound pressure level at a distance of 1 m (indoors)
3.6
Heating water flow
with an internal pressure differential of
3.7
Free pressure, heating circulating pump (max. stage)
3.8
Air flow rate
with an external static pressure differential of
3.9
Refrigerant; total filling weight
3.10 Lubricant; total filling weight
3.11 Output of electric heating element
(second heat generator)
4
Dimensions, connections and weight
4.1
Device dimensions
4.2
Device connections to heating system
4.3
Air duct inlet and outlet (min. internal dimensions)
4.4
Weight of the transportable unit(s) incl. packing
4.5
Buffer tank volume
4.6
Buffer tank pressure rating
5
Electrical Connection
5.1
Nominal voltage; fuse protection
5.2
Nominal power consumption
5.3
Starting current with soft starter
Nominal current A2 W35 / cos ϕ
5.4
6
Complies with the European safety regulations
7
Additional model features
7.1
Defrosting
Type of defrosting
Defrosting tray included
7.2
Heating water in device protected against freezing
7.3
Performance levels
7.4
Controller internal/external
1. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, other parameters, such as, in particular, the defrosting
capacity, the bivalence point and regulation, should also be taken into consideration. The specified values, e.g. A2 / W55, have the following meaning: External temperature 2 °C
and heating water flow temperature 55 °C.
2. The heat circulating pump is integrated.
3. See CE declaration of conformity
4. The heat circulating pump and the heat pump manager must always be ready for operation.
EN-12
All manuals and user guides at all-guides.com
°C / °C
°C
1
at A-7 / W35
kW / ---
1
at A-7 / W45
kW / ---
1
at A2 / W35
kW / ---
1
at A7 / W35
kW / ---
1
at A7 / W45
kW / ---
1
at A10 / W35
kW / ---
dB(A)
dB(A)
2
m³/h / Pa
Pa
m³/h / Pa
type / kg
type / litres
kW
H x W x L cm
Inch
L x W cm
kg
l
bar
V / A
1
A2 W35
kW
A
A / ---
4
LIK 8TE
Compact
IP 20
Indoors
Up to 58 / above 18
-25 to +35
10.0
5.8 / 2.7
5.5 / 2.6
5.4 / 2.1
7.5 / 3.3
7.4 / 3.2
9.3 / 3.9
9.2 / 3.8
8.8 / 3.2
9.8 / 4.1
9.7 / 4.0
53 / 60
48.0
0.8 / 2700
1.6 / 11900
45000.0
2500 / 20
R404A / 2.0
Polyolester (POE) / 1.5
2.0
190 x 75 x 68
G 1'' external
44 x 44
264
50
6
400 / 25
2.27
19.5
4.1 / 0.8
4.2 / 0.8
3
Automatic
Reverse cycle
Yes (heated)
Yes
1
Internal
5.0
2.33

Publicité