D+H KA 34-K-BSY+ Notice Originale page 5

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

WARNING
Read all safety warnings, instructions, illustrations
and specifications provided with this product.
Failure to follow all instructions listed below may
result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future
reference.
Safety notes
Operating voltage 230 V AC!
Risk of injury from electric shock!
Do not reverse L+N! Connect PE!
Do not connect directly to the mains supply!
- Connection has to be carried out only by an
authorized electrical specialist
- Danger of violent pressure in handaccessible area
- Keep away People from the operating area of the
drive
- Keep away children from the control
- Observe pressure load diagram of the chain!
- Use only in dry rooms
- Only for inside mounting.
Use rain detector with danger of rain
(e.g. at domelights or roof windows)
- This product may not be operated without the
covering stoppers, which are delivered with
bracket sets
- Just use unchanged original D+H parts
- Observe mounting instructions of bracket set!
Observe enclosed r ed safety slip!
Extent of supply
Drive unit with 2,5 m silicone cable. Dependent on
the type of window, different bracket sets are
available separately.
Mounting informations
Mount the drives mechanical
stress-free. With that, a better
load distribution is ensured
on all the drives.
99.823.97 2.8/10/21
Intended use
- Chain drive for electric opening and closing of
windows and flaps in the facade and roof area
- Operating voltage 230 V AC
- Useable for smoke ventilation, D+H Euro-SHEV
according to DIN EN 12101-2 as well as daily
natural ventilation
- Only for inside mounting
Performance features
- Micro processor controlled synchro electronics
BSY + for a precise synchronous run
- Individually programmable (via software SCS)
- Protection system for the main closing edge
- Locking relief after closing
Pressure load diagram
Observe maximum pressure load of the chain!
Maximum pressure load of the chain is not
automatically identical with maximum pressure force
of the drive!
A t v e r t i c a l a c t i v e p u l l i n g
application (e.g. for a skylight) the
forces must be rearranged by
software SCS.
English
500
400
300
200
100
0
Stroke / (mm)
If after mounting the measure x is
as bigger as 23 mm, null balance
with software SCS is neccesary.
Closure Ranges will shift in
relation to new zero point.
≥ 23 mm ?
KA34/54-K-BSY+ Set
X
5/16

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ka 54-k-bsy+Ka-k-bsy+ set

Table des Matières