Before Mounting; Important - Bircher Reglomat Herkules 2 Mode D'emploi D'origine

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN ISO
9001
Quality
Herkules
international
level
Translation of the original operation instraction
1
Safety instructions
The unit may only be operated from a protection low-voltage
system with electrical separation. The unit may only be opened
and repaired by the supplier.
Never touch any electronic components of the detector
Description of the detector
2
Herkules 2
Microwave motion detector
for industrial doors
3
7
1
5
4
15
9
Housing
1
Front cover
2
Rear wall
3
Mounting bracket
4
Fastening
5
Cover screws
6
8-pin cable
7
Microwave planar module
8
Screw terminal
9
3
Mounting
3.1

Before Mounting

Field geometry: Select whether a narrow or wide field geometry
should be used. The clip must be used for the wide field.
Note:The clip can be used for mounting heights up to max. 4 m.
It is not mounted on delivery. (However, it is stuck onto the rear of the
antenna.)
1
3
2
5
8
12
13
14
11
6
10
2
Key
10
X
Key
1 1
Y
Switch addressing
12
13
LED red
LED green
14
Clip
15
2

IMPORTANT:

Fit the clip correctly!
Microwave motion detector
If the device is already connected, interrupt the power supply for
4
5 seconds.
5
After mounting, activate the wide field with the remote control (B+1).
Addressing: Each detector can be assigned an address (1–4 with DIP
switch and 5–7 with remote control). Different addresses are necessary
when several detectors are within the range of a remote control.
Other addresses 5, 6 + 7 can be set using the remote control
(F+8+5...7)
Mechanical mounting
3.2
– The detector must be firmly mounted on a flat surface. (Avoid
vibrations)
– Objects such as plants, flags, fans etc. must not protrude into
the detection area.
– The detector must not be obscured by covers/signs
– Fluorescent lamps should not be placed in the immediate
vicinity of the detection area
– Mount the device in the middle above the industrial door
73.5 (2.89")
1. Affix drilling jig to wall or ceiling and drill holes according to values
given.
2. Route cable through opening provided in mounting bracket and
make sure length is sufficient for wiring.
3. Screw mounting bracket on tightly
4. Hook detector into mounting bracket and set detector to required
angle. Standard angle: 30°
5. Connect cable according to type plate.
Wall mounting:
125
for industrial doors
Adress 1*
Adress 2
Adress 3
Adress 4
55 (2.17")
Use the drilling jig enclosed
in the packaging!
Ceiling mounting:
125
41
50
min. 50
Page 1