Bircher Reglomat Herkules 2 Mode D'emploi D'origine page 14

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.7
Adjusting the detector
The settings are identified as follows:
e.g. D+... Remote control menu
e.g. P.1... Primary programming mode with keys, function no. 1
e.g. S.3... Secondary programming mode with keys, function no. 3
5.8
Mounting height F+4
F + 4 + 1...7
P.2+1...7 (keys)
1 = 2.0 bis 2.4 m
5 = 5.0 bis 5.9 m
2 = 2.5 bis 2.9 m
6 = 6.0 bis 6.9 m
3 = 3.0 bis 3.9 m
7 = 7.0 bis 7.9 m
4 = 4.0 bis 4.9 m
It is essential to adjust the mounting height if it does not match the
factory setting.
5.9
Comfort functions C
These pre-programmed settings allow you to configure the system
quickly and easily for standard applications.
Remote
Function
control
C + 1
Standard, detects all objects
C + 2
Frontal traffic, all objects
C + 3
High-speed industrial door, all objects
C + 4
Detects slow movements, all objects
Standard, differentiation between people and
C + 5
vehicles
Frontal traffic, differentiation between people
C + 6
and vehicles
C + 7
High-speed industrial door, people suppression
Detects slow movements, differentiation
C + 8
between people and vehicles
Note: The selected enhanced function is only read back and displayed
as such if no parameters were changed. Please refer to the table of
enhanced functions in 4.6 for more details.
5.10
Field size D
D + 1...9
P.4+1...9 (keys)
Levels 1 (small field) to 9 (large field)
Refer to the technical data for field dimensions.
5.11
Relay hold interval F+1
F + 1 + 1...4
S.1 + 1...5 (keys)
1 = 0.2 s
2 = 0.5 s
3 = 1.0 s
4 = 2.0 s
5 = 5.0 s
The relay hold interval only starts after other functions have been com-
pleted (delayed).
5.12
Direction recognition E+1
Remote
Function
control
E + 1 + 1
Forwards, movement towards detector
E + 1 + 2 Backwards, movement away from detector
E + 1 + 3 Forwards and backwards
Page 6
5.13
Relay parameter settings E+2
Remote
Function
control
Standard industrial door, differentiation between
E + 2 + 1
people and vehicles
E + 2 + 2
Standard industrial door, people suppression
E + 2 + 3
Standard industrial door, vehicle suppression
Standard industrial door, people and vehicles,
E + 2 + 4
same output (relay 2)
Standard industrial door, people and vehicles,
E + 2 + 5
outputs with direction segregation
High-speed industrial door, people suppression
E + 2 + 6
(relay 2)
High-speed industrial door, people and vehicles,
E + 2 + 7
same output (relay 2)
High-speed industrial door, people and vehicles,
E + 2 + 8
outputs with direction segregation
Please also refer to the table of relay parameter settings in point 4.6!
5.14
Crossing traffic masking CTM F + 5
CTM prevents an industrial door from being inadvertently opened by vehi-
cles or persons that are only moving or walking past it but do not want to
pass through the industrial door.
F + 5 + 1 = Aus
F + 5 + 2...9
Keys
Industrial door remains closed
P.1+1
to crossing traffic (level 9)
P.1+2
P.1+3
P.1+4
P.1+5
Industrial door opens to crossing traffic
or when an object approaches laterally
P.1+6
(level 1)
P.1+7
P.1+8
Optimum inclination angle for crossing traffic function: 30° to 45°
Crossing traffic masking is not possible with the clip!
5.15
Wide field B
B + 1 = On
B + 2 = Off
Field without clip
This option must be activated when the mechanical clip is used for set-
ting a wide field. Please refer to 3.1 for information about clip mounting.
The detector will not function correctly if the wrong setting is made.
5.16
Slow Motion Detection (SMD) F+3
Keys
The slightest (quasi-static) movements are detected as soon as the detec-
tor is activated. The detector only issues the corresponding signal to the
S.2 + 1
industrial door controller if no more movement is registered during the set
S.2 + 2
monitoring period. Sensitivity during this monitoring period can be set to
decrease or remain constant.
S.2 + 3
S.3 + 1
S.3 + 2...9
S.4 + 1
S.4 + 2
Field with clip
Keys
P.3 + 1
P.3 + 2
P.3 + 3
P.3 + 4
P.3 + 5
P.3 + 6
P.3 + 7
P.3 + 8

Publicité