Explanation of functions and settings
5.1
General description of the remote control
The Reglobeam remote control allows you to program Herkules 2 easily
and conveniently from the ground. Data transfer between Reglobeam and
Herkules 2 functions in both directions, i.e. to and from the detector, and
is guaranteed by an infrared interface. The Reglobeam reads back the
adjusted values immediately after programming and displays them for
control purposes. This ensures safe and correct programming.
5.2
Function of the «Reglobeam» remote control
The «Reglobeam» remote control functions using a combination of func-
tions and number keys. Take care to operate it correctly as described in
chapter 4.2.
Flashing keys on the Reglobeam indicate that the data has not been fully
transmitted. Avoid exposing the infrared interface to direct sunlight or
other light sources.
Layout of the «Reglobeam» remote control
5.3
Infrared interface
Numerical keys
to
1
9
Function keys
to
A
F
Start
G
Front side
5.4
Configuration mode
The connection between the Reglobeam and Herkules 2 can only be
established when the detector is in configuration mode. Configuration
mode is activated when the detector is switched on. For safety reasons,
this mode is automatically deactivated 30 minutes after the last setting
has been made on the detector. Configuration mode can be exited at any
time by pressing keys A+4.
Configuration mode can be activated in three different ways:
a) By pressing any key X or Y key on the detector
Key
X
b) By restarting the detector (disconnecting the supply voltage)
c) Access via remote control with access code
Battery
compartment
Locking
screw
Rear side
Key
Y
5.5
Establishing the connection
Press start key G on the Reglobeam
  If the connection has been established successfully, G and one of the
keys 1 to 7 light up (address of the detector)
  If G flashes, the connection could not be established
  Hold the remote control closer to the detector and point directly at it
  Check the batteries of the Reglobeam.
  Replace the batteries if nothing lights up.
  Configuration mode is not activated if G and one of the keys 1 to 7
light up although no further settings are possible.
Please refer to the first part (4.6) for an overview of individual parameters
and the enhanced level settings.
Note: Programming must be carried out within 30 s. If this time elapses,
it is necessary to activate programming mode again (press key G
5.6
Configuration with keys
Key
X
Primary mode:
Press keys X and Y simultaneously and hold for 2 s
  Green LED lights up, then release
Secondary mode:
Press keys X and Y simultaneously and hold for 4 s
  Red LED lights up, then release
Reset:
Press keys X and Y simultaneously and hold for 8 s
  Both LED lights up, then release
Mode
Parameter (key X)
Enhanced level
Mounting height
Primary
Relay parameter setting
Field size
Relay hold interval
Direction recognition
Crossing traffic masking
Sekundär
Wide field
SMD level
SMD field size
Digital filter function
Changing the function
Press key X. The value increases by 1 for every key press (function no.).
Once the last function has been reached, the program jumps back to the
first function. The green LED then indicates the number of the activated
function.
Changing the level
Press key Y. The value increases by 1 for every key press (level). Once the
last level has been reached, the program jumps back to the first level.
Exiting programming mode
Exit programming mode by pressing both keys X and Y briefly at the same
time.
Procedure
Press keys X and Y at the
same time to access the
Key
Y
required mode.
Function no. Level key Y
1
2
3
4
1
2
3
4
5
6
7
1–8
1–7
1–8
1–9
1–5
1–3
1–9
1–2
1–9
1–9
1–2