Maintenance And Cleaning - Bosch GAS 50 M PROFESSIONAL Instructions D'emploi

Masquer les pouces Voir aussi pour GAS 50 M PROFESSIONAL:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
1 609 929 K11.book Seite 16 Freitag, 1. Dezember 2006 12:33 12

Maintenance and Cleaning

Before any work on the machine itself, pull
the mains plug.
Always keep the machine clean.
At least once every year a dust-technical test is
to be carried out by the manufacturer or a
trained professional, e. g. to check for damage
to the filter, tightness of the machine and func-
tion of the control machine.
For class M vacuum cleaners which have been
used in contaminated areas, the exterior and all
unit parts should be cleaned or treated with
sealants. All contaminated parts that cannot be
cleaned satisfactorily during maintenance and
repair must be disposed of. Such parts must be
disposed of in impermeable bags, in accord-
ance with the relevant regulations for the dis-
posal of such waste materials.
For maintenance carried out by the user, the
unit must be dismounted, cleaned and main-
tained as far as possible without presenting any
danger to the maintenance personnel or other
persons. In order to prevent possible danger,
the vacuum cleaner should be cleaned prior to
dismounting. The area in which the vacuum
cleaner will be dismounted should be well venti-
lated. Wear personal protective equipment dur-
ing maintenance. After the maintenance, the
maintenance area should be cleaned.
If the machine should fail despite the care taken
in manufacturing and testing procedures, repair
should be carried out by an authorized after-
sales service agent for Bosch power tools.
In all correspondence and spare parts orders,
please always include the 10-digit article
number given on the nameplate of the vacuum
cleaner.
WARNING! This appliance must be earthed.
Important instructions for connecting a new
3-pin plug.
The wires in the cable are coloured according to
the following code:
strain relief
live = brown
earth = green/yellow
neutral = blue
Do not connect the blue or brown wire to the
earth terminal of the plug.
Important: If for any reason the moulded plug is
removed from the cable of this machine, it must
be disposed of safely.
16 | English
All manuals and user guides at all-guides.com
Removing/Replacing the
Folded Filter (see figure
With a coin or similar, rotate the lock 8 by
1
/
4
lock in.
Fold up the cover of the vacuum top, grasp the
folded filter by the fins, pull up and remove.
Replace a damaged filter immediately.
Insert new folded filters, and ensure that they
are seated tightly.
Fold the cover down again. With slight pressure
from above on the cover, the lock 8 will snap
back again.
Container
Wipe out the container 11 from time to time with
a commercially available, non-scouring cleaning
agent and allow to dry.
Motor Protection Filter (see figure
The motor protection filter 19 is basically main-
tenance-free. Take out the motor protection filter
from time to time and flush it. Allow to dry thor-
oughly before reinserting.
Level sensors
20
20
Clean the level sensors 20 occasionally.
Unlock the latches 13 and remove the vacuum
top 3.
Clean the level sensors 20 with a soft cloth.
Reattach the vacuum top 3 again and lock the
latches 13.
To be fitted
by a qualified
professional only
turn in the direction of the arrow and push the
)
B
)
B
1 609 929 K11 • 1.12.06

Publicité

Table des Matières
loading

Table des Matières