Manual cleaning of the panel filter:
This operation must be performed with the machine switched off and the key removed.
If the action of the filter shaker proves insufficient, proceed as follows to clean the filter manually.
Remove the filter compartment cover.
Lift the two levers and remove the filter shaker bracket complete with the filter shaker mo-
tor, carefully disconnecting the power cable from the filter shaker (fig. 23).
Remove the suction filter (fig. 23).
Blow the filter clean with compressed air (maximum pressure 6 bar).
The filter is marked to show the correct direction for fitting.
23
Manual cleaning of the pocket filter:
This operation must be performed with the machine switched off and the key removed.
If the action of the filter shaker proves insufficient, proceed as follows to clean the filter manually.
Remove the filter compartment cover.
Unscrew the four screws securing the two filter holder brackets (fig. 24).
Remove the two brackets (fig. 24).
Remove the filter, carefully disconnecting the power cable from the filter shaker (fig. 24).
Blow the filter clean with compressed air (maximum pressure 6 bar).
24