Move the cursor to the item and select the parameter.
Unit Number
In an RS485 chain each unit must have a unique number.
Sub Address
Do not set.
Baud Rate
Specifies the transmission speed (2 400, 4 800, 9 600, 19 200 bit per second) for the RS485
communication.
Data Bit
Specifies the number of data bits (7 or 8 bits) for the RS485 communication.
Parity Check
Specifies the parity check mode (NONE, ODD, EVEN).
Stop Bit
Specifies the number of stop bits (1 or 2 bits).
X ON/X OFF
Specifies whether to apply flow control or not (USE or NOT USE).
Wait Time
Specifies the time to wait until retrying after confirming that no data is received from the con-
troller. (OFF: no retry, 100, 200, 400, 1 000 ms).
Alarm Data
Specifies the alarm transmission mode.
POLLING: Transmits the alarm data in response to requests from the controller.
AUTO 1: Transmits the alarm data each time an alarm signal is received by the camera.
AUTO 2 (Default): Transmits alarm data at intervals of 5 seconds.
Delay Time
Specifies the time to transmit the acknowledge request when communicating on a
2-line connection.
[----, 100 ms] Factory default setting: ---- (no set).
This menu appears only when a 2-line communication is used. Make sure to be 100
ms when connecting the camera with the Video Multiplexer or the Matrix Switcher in a 2-line
communication system.
The settings become effective with the closing of SETUP menu.
Note: Set the same parameters for the cameras, controllers and personal computers in an
RS485 chain.
■ Password Lock Setting
Caution: For security, do not operate your VTR for recording while the password menus are
displayed on the monitor.
A 3-digit number is used for a password to limit access to all settings.