Internal Connection Diagram
3.6 kΩ
If you use a lens control terminal, you should not use GND but the COM terminal.
*
The COM terminal is used in common with ZOOM, FOCUS, and IRIS.
*
To change the polarity of "+" or "-", make a changeover with the SETUP MENU of ZOOM
*
INVERSE or FOCUS INVERSE.
Alarm Output Terminal
Connect an external device such as a buzzer or lamp to the ALM OUT terminal.
DAY/NIGHT Input Terminal
Connect an external sensor to the DAY/NIGHT IN terminal.
Notes:
Use a relay unit if the voltage or current of the connected device exceeds the rating.
To validate the Day/Night function, set BW mode to EXT on the menu.
A/D Control Input Terminal
This camera can be controlled through the A/D IN terminal by means of an analog voltage or a
resistance shunt circuit specified below.
A/D IN
GND
12
3.6 kΩ
3.6 kΩ
0.1 µF
6.8 kΩ
8.2 kΩ
TELE
WIDE
NEAR
ZOOM
FOCUS
IRIS
COM
12 kΩ
18 kΩ
33 kΩ
FAR
OPEN
CLOSE
external
controller
etc.
68 kΩ
180 kΩ
AF DAY/NIGHT

Publicité