13
TROUBLE SHOOTING
A wired remote controller is necessary for this function. This function cannot be operate with a wireless
remote controller.
Confirmation and check
When a trouble occurred in the air conditioner, the
check code and the indoor UNIT No. appear on the
display part of the remote controller.
The check code is only displayed during the
operation.
If the display disappears, operate the air
conditioner according to the following "Confirmation
of error history" for confirmation.
Check code
Confirmation of error history
When a trouble occurred on the air conditioner, the
trouble history can be confirmed with the following
procedure. (The trouble history is stored in memory
up to 4 troubles.)
The history can be confirmed from both operating
status and stop status.
2
3
1
Procedure
When pushing
and
for 4 seconds or more, the following display
appears.
If [Service check]
is displayed, the mode enters
in the trouble history mode.
• [01: Order of trouble history] is displayed in
CODE No. window.
• [Check code] is displayed in CHECK window.
• [Indoor unit address in which an error occurred]
is displayed in UNIT No.
Indoor UNIT No. in which
an error occurred
1
buttons at the same time
2
Procedure
Every pushing of "TEMP."
set temperature, the trouble history stored in
memory is displayed in order.
The numbers in CODE No. indicate CODE No. [01]
(latest) → [04] (oldest).
REQUIREMENT
Do not push
button because all the trouble
history of the indoor unit will be deleted.
3
Procedure
After confirmation, push
usual display.
– 26 –
Installation Manual
button used to
button to return to the
26-EN