Repairs; Inlet Valve Pusher; Inlet Valve - Titan ELITE 4500 Manuel D'entretien

Groupe de projection à haute pression
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

REPAIRS

2
REPAIRS
Prior to making any repairs, make sure to perform
the Pressure Relief Procedure, section 4.5 of the
Operating Manual (form no 2418919).
2.1

INLET VALVE PUSHER

1. Use a 17 mm wrench to screw out the inlet valve button
(Fig. 15, item 1).
2. Replace the wiper (2) and O-ring (3).
2.2

INLET VALVE

1. Place a 30 mm wrench on the housing (Fig. 16, item 1).
2. Loosen the housing (1) with light blows of a hammer on
the end of the wrench.
3. Screw out the housing with the inlet valve (2) from the
paint section.
4. Remove the clasp (3) using a screwdriver.
5. Place the 30 mm wrench on the inlet valve (2). Turn out the
inlet valve carefully.
Never pry the valve out or damage to the housing
will occur.
Attention
6. Clean the valve seat (4) with a cleaning agent and brush
(ensure that no brush hairs are left behind).
7. Clean the seals (5, 6) and check for damage. Replace, if
necessary.
8. Check all the valve parts for damage. In case of visible wear
replace the inlet valve.
8
INSTALLATION
1. Insert the inlet valve (2) into the housing (1) and secure with
2. Screw the unit from the housing and the inlet valve into
3. Tighten the pusher housing with the 30 mm wrench and
2
3
1
the clasp (3). Ensure that the (black) seal (5) is mounted in
the pusher housing.
the paint section. The same (black) seal (6) has to be
mounted in the paint section.
tighten with three light blows of the hammer on the end
of the wrench. (Corresponds to approx. 90 Nm tightening
torque).
2
ELITE 4500
6
4
5
3
1

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

24073102407311

Table des Matières