Télécharger Imprimer la page

Festo CPV GE-IB-8 Serie Mode D'emploi page 21

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 33
6
Technical specifications
Type
Temperature range
– Operation
– Storage
Relative humidity
Protection class as per EN 60529 plug
connector inserted or provided with
protective cap
Protection against electric shock
(protection against direct and indirect
contact as per EN 60204-1/IEC 204)
Protection against explosion
(as per EU guideline 94/9/EG,
EN 50021 and EN 50281-1-1)
Do not disconnect electrical connec-
tions which are under tension.
Electromagnetic compatibility
– Interference emitted
– Resistance to interference
*)
The CP valve terminal can also be used with individual authorisation
in residential areas (living, business and commercial areas, small
firms).
Festo CPV..-GE-IB-8 0108NH English
CPV..-GE-IB-8
- 5 °C ... + 50 °C
- 20 °C ... + 70 °C
95 %, non-condensing
IP65
With a PELV power unit
(Protected Extra Low
Voltage)
II 3 G/D EEx nA II T5 X
- 5 °C ≤Ta ≤+ 50 °C
T 80 °C IP65 (year of manu-
facture see Ex-identification
on the product)
Tested as per EN 50081-2
(industry)
Tested as per EN 61000-6-2
(industry)
21

Publicité

loading