Group S.p.A.

GENERAL INFORMATION

The single-family door entry monitor kits Art. 8495W, 8495B and two-
family door entry monitor kits Art. 8496W, 8496B can be used in
residential or service sector buildings where effective access control
and simple installation procedures are required.
In effect it only requires 2 wires between the external unit and the
internal monitor(s) to activate the system (calls, audio, video, self-
ignition), plus two wires to supply 12V AC power to the external unit
and electric lock.
A wide range of accessories is also available to deal with the
requirements of any type of system in addition to interesting standard
accessories, the system can also be extended by adding door entry
monitors and/or door-entry phones and/or external units.
In this way it is possible to have a maximum of two external units with
three internal units including door-entry phones and door entry
monitors for the single-family configuration, and two external units
with six internal units including door-entry phones and door entry
monitors (three for each call button) for the two-family configuration.
By means of appropriate settings (according to the table on page 34)
single-family intercoms (i.e. between users with the same user code)
and two-family intercoms (i.e. between users with different user
codes) are possible using door entry monitors as well as door-entry
phones.
Several kits can be connected to a Simplebus main entrance panel
and/or a switchboard Art. 1998A.

EXTERNAL UNITS

Art. 4875KC - 4876KC

Technical characteristics
Connection to the monitor with 2 wires for audio, video, lock-release
and call plus 2 wires for power supply from Art. 1205/B.
High sensitivity, adjustable camera with 1/3" CCD sensor. White LED
illumination.
Microphone and speaker volume adjustment. Aluminium call button
with label which can be removed from the front. Die-cast aluminium
module-holder frame.
Flush-mounted box dimensions: 127x127x45 mm.
The button of article 4875KC is factory-set to call address 1, whereas
for article 4876KC the buttons are set to call addresses 1 (left button)
and 2 (right button).
External unit dimensions: 125x125 mm.
Description of terminal block
LL monitor connection (video, call, audio, lock-release)
SE-SE electric lock connection
~ ~ external unit power supply
PR programming terminal
- negative terminal to be used in programming stage
S programming terminal
RTE request to exit button input OCC., V+ (not used)
MT KIT 14
22
Technical characteristics
The transformer provides 2 outputs: one to supply the external unit
and the electric lock, and the other to supply the monitor.
Dimensions: 105x85x85 mm (6 DIN modules).
500mA delayed protection fuse.
Description of terminal block
AC230V mains voltage input
~~ AC output for external unit and electric lock
+ - monitor power supply 20V DC output
2

Art. 1205/B