8. Troubleshooting
8.1 Twister (No. 1826)
Error
ON/OFF switch
fails to work.
Motor fails to
start.
No, or insufficient
vacuum (not in
the green range
on the scale).
Vacuum release /
venting, too slow.
Vacuum pump
doesn't start.
The vacuum pump
switches on and
off intermittently
during the mixing
process.
8.2 Twister venturi (No. 1827)
Error
ON/OFF switch
fails to work.
Motor fails to
start.
No, or insufficient
vacuum.
EN
Cause
Power not connected.
Device fuse blown.
Motor fault.
Suction filter system
plugged.
Seal surfaces dirty.
Solenoid valve fault.
Vacuum pump fault.
Suction filter system
plugged.
Solenoid valve fault.
Bowl detection pin stick-
ing.
At <100% vacuum, the
vacuum pump will switch
off once the set vacuum
has been reached.
Cause
Power not connected.
Device fuse blown.
Motor fault.
Compressor switched
off.
Operating pressure too
low or too high.
Compressed air hose
not connected, leaky or
bent.
Air hose too long.
Square are of air hose
too small.
Suction filter system
plugged.
Check the power supply.
Replace the fuse (Sec. 3.4).
Have the device repaired.
Have filter cleaned or changed
(Sec. 3.3).
Clean the seal surfaces (Sec. 3.2).
Have the device repaired.
Have the device repaired.
Have filter cleaned or changed
(Sec. 3.3).
Have the device repaired.
Clean area around pin.
Have the device repaired.
None
If the vacuum should drop due to
seepage, the vacuum pump will
automatically switch back on until
the set vacuum level has been
reached.
Check the power supply.
Replace the fuse (Sec. 3.4).
Have the device repaired.
Switch the compressor on.
Check dynamic operating pressure
(see technical data, Sec. G.2).
Switch off other consumers.
Check the hose.
Maximum length 2 m.
Minimum inner diameter 4 mm.
Have filter cleaned or changed
(Sec. 3.3).