Operating Elements And Connections; Safety Notes; Applications; Setting The Spotlight Into Operation - IMG STAGELINE PARC-56/RGB Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20
All operating elements and connections de -
GB
scribed can be found on page 2.
1 Operating Elements
and Connections
1 XLR chassis plug DMX INPUT: DMX signal
input for connecting a light controller or the DMX
signal output of another spotlight
2 Clip to secure the barn doors
3 XLR jack DMX OUTPUT: DMX signal output for
connecting the DMX input of another DMX-con-
trolled unit
4 Mains cable for connection to a socket
(230 V~/ 50 Hz)
5 Locking screws for the mounting brackets
6 Mounting brackets / stand
7 Buttons to select the operating mode and to
change settings via the menu
8 Display

2 Safety Notes

The spotlight corresponds to all relevant directives
of the EU and is therefore marked with
WARNING The spotlight uses dangerous mains
voltage. Leave servicing to skilled
personnel and do not insert anything
into the air vents; inexpert handling
may result in electric shock.
G
The spotlight is suitable for indoor use only. Pro-
tect it against dripping water and splash water,
high air humidity and heat (admissible ambient
temperature range: 0 – 40 °C).
G
Do not operate the spotlight or immediately dis-
connect the mains plug from the socket
1. if the spotlight or the mains cable is visibly
damaged,
2. if a defect might have occurred after a unit was
dropped or suffered a similar accident,
3. if malfunctions occur.
In any case the spotlight must be repaired by
skilled personnel.
G
A damaged mains cable must be replaced by
skilled personnel only.
G
Never pull the mains cable to disconnect the
mains plug from the socket, always seize the plug.
G
No guarantee claims for the spotlight and no lia-
bility for any resulting personal damage or mate-
rial damage will be accepted if the spotlight is
used for other purposes than originally intended,
if it is not safely installed or not correctly con-
nected or operated, or if it is not repaired in an
expert way.
12
G
Important for U. K. Customers!
The wires in this mains lead are coloured in ac -
cord ance with the following code:
green/yellow = earth
blue = neutral
brown = live
As the colours of the wires in the mains lead of
this appliance may not correspond with the
coloured markings identifying the terminals in
your plug, proceed as follows:
1. The wire which is coloured green and yellow
must be connected to the terminal in the plug
which is marked with the letter E or by the earth
symbol , or coloured green or green and yellow.
2. The wire which is coloured blue must be con-
nected to the terminal which is marked with the
letter N or coloured black.
3. The wire which is coloured brown must be con-
nected to the terminal which is marked with the
letter L or coloured red.
Warning – This appliance must be earthed.
If the spotlight is to be put out of operation
definitively, take it to a local recycling plant
for a disposal which is not harmful to the
.
environment.

3 Applications

This LED spotlight is used for illumination, e. g. on
stage, in discotheques and function rooms. The
light source is a high-power RGB COB LED (COB
= chip-on-board technology): Many individual LEDs
in the colours red, green and blue are mounted
close together on a chip, thus providing a uniform
light distribution.
The spotlight is designed for control via a DMX
light controller (3, 4, 5 or 10 DMX control channels),
but it can also be operated independently without a
controller.
Offering a special feature, the spotlight supports
66 subaddresses for DMX operation. Thus, it is
possible to independently control up to 66 spot-
lights (spotlight groups) via one DMX start address
and the maximum number of DMX units that can be
controlled is substantially increased.

4 Setting the Spotlight into Operation

4.1 Installation
G
Always position the spotlight in such a way to
ensure sufficient air circulation during operation.
Never cover the air vents of the housing.
G
Always keep a minimum distance of 50 cm to the
illuminated object.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Parc-64/rgb38.668038.6760

Table des Matières