Operating Elements And Connections; General Safety Notes - IMG STAGELINE LSE-3LRG Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
All operating elements and connections de -
GB
scribed can be found on the fold-out page 3.
1 Operating Elements
and Connections
1 Setscrew (2 ×) for the mounting bracket
2 Relief pane for scattering the laser beams and
the LED light
3 Lens for the laser beams
The lens is at the same time the outlet area of
the laser beams.
4 Mounting bracket
5 Control RED STROBE for the lighting time of
the red laser beam in the MANUAL mode
In position MAX a continuous beam is pro-
duced.
6 Control GREEN STROBE for the lighting time of
the green laser beam in the MANUAL mode
In position MAX a continuous beam is pro-
duced.
7 Control SENSITIVITY for the sensitivity of
response in case of music control via the micro-
phone (8)
8 Microphone for music control
9 Safety lug to fix a safety rope
10 Mains jack for connection to a socket (230 V~ /
50 Hz) via the supplied mains cable
11 Control DIMMER for the brightness of the blue
LED basic illumination
12 Control ROTATION SPEED for the rotation
speed of the relief pane (2)
13 Sliding switch for the operating mode
It is used to select the control mode for switch-
ing the laser beams on and off
MANUAL manual control via the controls
RED STROBE (5) and
GREEN STROBE (6)
MUSIC
music control via the microphone (8).
Adjust the sensitivity of response with
the control SENSITIVITY (7).
AUTO
automatic control programme
14 Support for the mains fuse
Only replace a blown fuse by one of the same
type
15 On / off switch
16 Key switch to switch on the laser beams
The key is used by the laser protection adviser
to secure the unit against unauthorized oper -
ation.
8
2 Safety Notes
The unit corresponds to all required directives of
the EU and is therefore marked with
2.1 Notes especially for laser units
This laser corresponds to the class 3b. The lasers
have the following power and wavelengths:
green laser
red laser
WARNING 1.The unit must be installed so that
nobody will be able to look directly
into the laser beam. Already a short
radiation on the retina may cause
permanent damage. Unintentional
reflections must be prevented.
2. The laser area must be limited and marked dur-
ing operation.
3. A laser protection adviser must be appointed in
writing and be present during operation (regu-
lation BGV B2 of the German employerʼs liabil-
ity insurance).
4. The operation of the laser must be notified at
the employerʼs liability insurance association
and the trade board.

2.2 General safety notes

WARNING The unit is supplied with hazardous
mains voltage. Never make any
modification on the unit and do not
insert anything through the air vents!
This may cause an electric shock
hazard.
It is essential to observe the following items:
G
The unit is suitable for indoor use only. Protect it
against dripping water and splash water, high air
humidity, and heat (admissible ambient tempera-
ture range 10 – 40 °C).
G
Do not place any vessels filled with liquid, e. g. a
drinking glass, on the unit.
G
Do not set the unit into operation, and immedi-
ately disconnect the mains plug from the mains
socket if
1. there is visible damage to the unit or to the
mains cable,
2. a defect might have occurred after a drop or
similar accident,
3. malfunctions occur.
The unit must in any case be repaired by skilled
personnel.
.
Power
Wavelength
40 mW
532 nm
100 mW
650 nm

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

38.5200

Table des Matières