Orange light
10 W - 24 V bulb MAXIMUM - use of a bulb with power greater than 10 W-
24 V can cause drive malfunctions.
Operation of the orange light
The orange light flashes while the gate is moving.
Area lighting
This accessory is not compatible with solar power.
Only use halogen or incandescent bulbs for area lighting, 500 W maximum.
Area lighting operation
Area lighting comes on each time the motor is switched on. It goes out automatically
1 minute and 30 seconds after movement has finished.
Backup battery
This accessory is not compatible with solar power.
The backup battery ensures the operation of the gate in the event
of an electrical power failure.
To increase the operation time of the battery during use, the wired
controls are deactivated and the gate can only be controlled using
the remote controls and the radio control points.
The indicator light
flashes (1 pulse) when the motor is battery-
operated.
Battery technical specifications
• Battery life: 10 continuous cycles or 24 hours on a gate in
perfect condition.
• Optimum charging time before using the battery: 48 hours.
• Service life: 3 years.
To ensure an optimum battery life, switch the gate's electric
power supply off at least 3 times a year to run a number of
cycles using the battery.
Key lock
This accessory is not compatible with solar power.