Connecting to the mains power supply

For your safety, these operations must be carried out with the power supply switched off.
Connecting the control unit to the mains power
Connect phase and neutral to terminals 16 and 17 (red "230 V"
label on the electronics)
Lock the 230 V power supply cable with the cable clamp
provided.
Fit a terminal block on the earth wire (yellow/green) and store
it in the control unit.

Commissioning

Switching the installation on

The indicator light
flashes (twice).
The motor is switched on and awaiting auto-programming.
If the indicator light
does not come on or the number of flashes is not as expected: see diagnostic page 16.

Storing the remote controls

If indicator light
is not lit, press button
1
electronics for 2 seconds.
The indicator light
Position the new remote control to be programmed on the
2
control electronics target.
Briefly press the button on the remote control to be
3
programmed. The RADIO indicator light will come on then
go out when you release the button on the remote control.
Complete opening is programmed on this button.

Auto-programming the gate leaves' travel

Prerequisites:
• Check that the installation is switched on: indicator light
flashes (2 flashes).
• The gate must be closed.
Press button 1 on the remote control to initiate a
1
COMPLETE opening motion of the gate. The leaves open
one after the other.
When the gate is completely open, press button 1 on the
2
remote control again to launch a FULL closing movement
of the gate.
Press button 1 on the remote control to initiate a
3
COMPLETE opening motion of the gate. The leaves open
with a slight delay.
When the gate is completely open, press button 1 on the
4
remote control again to launch a FULL closing movement
of the gate.
When the gate is completely closed, indicator light
the control unit should be CONTINUOUSLY LIT.
8
on the control
comes on.
1
2
>2s
1
2
3
4
of
Live
Cable clamp
230 V power supply cable
3
Neutral
<0,5s