Desa VO36NR Mode D'emploi page 8

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION
Continued
WARNING: Fireplace must
be operated only with doors
fully opened.
Door Adjustment
Remove doors and slightly loosen lower pivot
plate (if equipped) and upper spring clips.
Replace doors and fully close them. Use 1/8"
shims (any material) to level doors. Once the
proper setting is achieved, carefully open doors
enough so that you can access pivot and spring
clips with a Phillips screwdriver. Tighten screws
(see Figure 9).
Please read the following care and operation
guidelines before operating your appliance
or fireplace.
• Glass doors should be operated in the fully
open position only (see Figure 10).
• If doors are not fully open, the thermo disk
will automatically turn off burner. After unit
cools, burner will automatically turn on.
• When operating doors, do not slam shut or
abuse them.
• Always keep area below bottom edge of
doors clear from obstacles or debris.
• Do not operate this appliance if glass doors
are broken or damaged.
Side
Front
Face
Partially
Opened
Door
Figure 9 - Door Adjustment
Figure 10 - Bi-Fold Doors Fully Opened
8
Spring
Clip
N
P E
Y O
L L
F U
www.desatech.com
• Do not use abrasive liquids or cleaners for
cleaning of glass and door trims. Any house-
hold glass cleaner should suffice. Do not
clean doors when hot, allow the appliance
to cool before cleaning.
CONNECTING TO GAS SUPPLY
WARNING: A qualified service
person must connect heater to gas
supply. Follow all local codes.
WARNING: This appliance
requires a 3/8" NPT (National
Pipe Thread) inlet connection
to the control valve.
CAUTION: Never connect
propane/LP unit directly to the
propane/LP supply. This unit re-
quires an external regulator (not
supplied). Install the external
regulator between the unit and
the propane/LP supply.
WARNING: Never connect
natural gas fireplace to private
(non-utility) gas wells. This
gas is commonly known as
wellhead gas.
Installation Items Needed
Before installing heater, make sure you have
the items listed below.
• approved flexible gas hose and fittings
(supplied with appliance, if allowed by local
codes)
• external regulator (propane/LP models
only)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve*
• test gauge connection*
• sediment trap
• tee joint
• pipe wrench
* A CSA design-certified equipment shutoff
valve with 1/8" NPT tap is an acceptable al-
ternative to test gauge connection. Purchase
the optional CSA design-certified equipment
shutoff valve from your dealer.
119109-01G