IMPORTANT: Make sure fireplace is level. If fire-
place is not level, log set will not work properly.
Note: Your fireplace is designed to be used in
zero clearance installations. Wall or framing
material can be placed against any exterior
surface on the rear, sides, top or bottom of
your fireplace, except where standoff spacers
are integrally attached. If standoff spacers
are attached to your fireplace, these spacers
can be placed directly against wall or framing
materials.
Use dimensions shown for rough openings
to create the easiest installation (see Built-In
Fireplace Installation, page 6).
INSTALLATION CLEARANCES
WARNING: Maintain the
minimum clearances. If you can,
provide greater clearances from
floor, ceiling and adjoining wall.
Carefully follow these instructions. This will
ensure safe installation. Fireplace hood
must be used if combustible mantel material
is installed.
Minimum Wall and Ceiling Clearances (see
Figure 2)
A. Clearances from the side of the fireplace
cabinet to any combustible material and
wall should follow diagram in Figure 2.
Example: The face of a mantel, bookshelf,
etc. is made of combustible material and
protrudes 3
/
1
2
bustible material must be 4" from the side
of the fireplace cabinet (see Figure 2).
B. Clearances from the top of the fireplace
opening to the ceiling should not be less
than 42".
Example
*Minimum 16" from Side Wall
Figure 2 - Minimum Clearance for
Combustible to Wall
119109-01G
INSTALLATION
" from the wall. This com-
www.desatech.com
C. When fireplace is installed on carpet-
ing or other combustible material, other
than wood flooring, fireplace should be
installed on a metal or wood panel extend-
ing the full width and depth of enclosure.
D. Clearances from bottom of fireplace to the
floor is 0".
CAUTION: Do not install
the fireplace directly on carpet
or vinyl.
WARNING: Fireplace hood
must be used if a combustible
mantel material is installed.
Mantel Clearances for Built-In Installation
If placing custom mantel above built-in fire-
place, you must meet the minimum allowable
clearance between mantel shelf and top of
fireplace opening shown in Figure 3, page
6. These are the minimum allowable mantel
clearances for a safe installation. Use larger
clearances wherever possible to minimize
the heating of objects and materials placed
on the mantel.
NOTICE: Surface temperatures
of adjacent walls and mantels be-
come hot during operation. Walls
and mantels above the fireplace
may become hot to the touch.
If installed properly, these tem-
peratures meet the requirement
of the national product standard.
Follow all minimum clearances
shown in this manual.
NOTICE: If your installation does
not meet the minimum clearances
shown, you must do one of the
following:
• raise the mantel to an accept-
able height
• remove the mantel
*
5