INSTALLATION
Continued
Wall board or facing
material (above
firebox) may be of
combustible material,
including decorative
mantel ornaments or
other similar projec-
tions off of the facing
material.
Framing
Material
Firebox
Wire-mesh
Screen
Figure 3 - Minimum Mantel Clearances
for Built-In Installation
BUILT-IN FIREPLACE
INSTALLATION
1. Frame in rough opening. The fireplace
framing should be constructed of 2 x 4
lumber or heavier. Use dimensions in
Table 1 and rough opening layout in Fig-
ure 4a. Adjust framing so that fireplace is
flush with finished wall surface. If installing
in a corner, use dimensions in Figures 4b
and 4c for rough opening.
2. Install gas piping to fireplace location (see
Connecting to Gas Supply, page 8.)
3. Carefully set fireplace in front of rough
opening with back of fireplace inside wall
opening.
4. Carefully insert fireplace into rough
opening.
5. Attach fireplace to wall studs using nails
or wood screws through holes in nailing
flange (see Figure 5).
IMPORTANT: When finishing your fireplace,
combustible materials such as wall board,
gypsum board, sheet rock, drywall, plywood,
etc. may be butted up next to the sides and top
of the fireplace. Combustible materials should
never overlap the fireplace front facing.
WARNING: Use only non-
combustible mortar or adhe-
sives when overlapping the front
facing with noncombustible
facing material.
6
Mantel Shelf
Note: Any portion of the
mantel shelf must NOT
extend beyond this profile.
12"
6
"
3
/
4
1
1
"
/
2
Noncombustible
Material May
12" 16" 20"
Project Off this
Surface above
the Firebox Hood
Note: All vertical
measurements are
Hood MUST
from top of fireplace
be used if
hood opening to
a combustible
bottom of mantel shelf.
mantel is
These minimum
installed.
clearances replace any
other recommended
clearances supplied
with your ANSI Z21.11.2
approved gas logs.
www.desatech.com
Table 1
Rough Opening Dimensions for built-in
Installation
Front Width
Model
(Inside to Inside) Height
36"
41
1
42"
48
5
(Minimum)
Height
(Inside to Inside)
37"
43"
TOP VIEW
Figure 4 - Rough Opening for Installing
Nails or Wood
Screws
Figure 5 - Attaching Firebox to Wall Studs
Depth
/
"
40
/
"
20
1
2
2
/
"
44
/
"
22
1
8
2
Depth
Figure 4a
Width
FOR 36"
MODELS
Figure 4b
45°
41
/
"
1
2
74"
TOP VIEW
FOR 42"
MODELS
Figure 4c
45°
48
5
/
"
8
86"
in Wall
Nailing
Flanges
119109-01G
(Min.)
/
"
3
4
/
"
5