Desa VO36NR Mode D'emploi page 18

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

WARNING: If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your
building.
• Immediately call your gas supplier from a neighbor's phone. Fol-
low the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
ObSERVED PRObLEM
Fireplace produces un-
wanted odors
Fireplace shuts off in use
Gas odor even when control
knob is in OFF position
Gas odor during combus-
tion
Dark residue on logs or
inside of fireplace
18
TROUbLEShOOTING
Continued
POSSIBLE CAUSE
1. Gas leak. See Warning
statement above
1. High or gusting winds
2. Low line pressure
3. Pilot is partially clogged
4. Inner vent pipe leaking
exhaust gasses into sys-
tem
5. Glass too loose and air
tight gasket leaks in corners
after usage
6. Bad thermopile or thermo-
couple
7. Improper vent cap instal-
lation
1. Gas leak. See Warning
statement above
2. Control valve defective
1. Gas leak. See Warning
statement above
1. Air holes at burner inlet
blocked
2. B u r n e r f l a m e h o l e s
blocked
3. Improper venting or ex-
cessive blockage
4. Excessive amounts of
embers and pan material
www.desatech.com
REMEDY
1. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 10)
1. Fireplace has been tested for
up to 40 mph winds. However,
extreme conditions may occur.
See Lighting Instructions on
page 12
2. Contact local propane/LP or
natural gas company
3. Clean pilot (see Cleaning and
Maintenance, page 14)
4. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 10)
5. Tighten glass
6. Replace faulty component
7. Check for proper installation
and freedom from debris or
blockage
1. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 10)
2. Replace control valve
1. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 10)
1. Clean out air holes at burner
inlets. Periodically repeat as
needed
2. Remove blockage or replace
burner
3. Have the vent system in-
spected, including the ter-
mination cap. Remove any
restrictions or obstruction
4. Clear excess embers until a
minimum gap of 1/2" remains
under the grate
119109-01G

Publicité

Chapitres

Table des Matières
loading

Table des Matières