AIR FLOW DIRECTION
8 AIR FLOW DIRECTION
8.1 RECOMMENDED AIR FLOW DIRECTION SETTING
LCD Indication
1 Step
RPK-(0.4-1.0)FSR(H)M
RPK-(1.5-4.0)FSR(H)M
8.2 ADJUSTING VERTICAL DEFLECTOR
The vertical deflector can adjust with moving by hand as shown
in the figures blow.
Vertical deflector
Louver
8.3 AUTOMATIC SETTING OF LOUVER
The swing louver is stopped and moved by controlling the remote control switch.
When "Stop" switch is pressed from the remote control switch, the swing louver will be closed automatically and the operation is
stopped.
9 EMERGENCY OPERATION
9.1 FUNCTION
The emergency operation switch is used when the batteries for
wireless remote control switch are shortage.
?
N O T E
The operation is as follows.
Automatic cooling/heating operation
Setting temperature: 25ºC
Fan speed: HIGH
Louver angle: horizontal
6
PMML0552 rev.1 - 02/2021 - A10635790A
2 Step
3 Step
4 Step
Model
COOL, FAN and DRY
5 Step
6 Step
7 Step
Step 3
Step 3
!
C A U T I O N
Do not move the louver by hand. If moved, the louver mechanism will be
damaged and the air flow direction may not be set.
Louver
RPK-(0.4-1.5)FSR(H)M: Press the temporary switch (ii)
RPK-(2.0-4.0)FSRM: Press the temporary switch with a non-
metallic tool,etc (iii)
The emergency operation is stopped when the temporary switch
is pressed again.
?
N O T E
Do not press the switch by metal sticks such as pen, pin, etc. It may cause
failure.
Auto Swing
HEAT
Step 7