Cause
Strong temperature vari-
ation
Auto-calibration not suc-
cessful
Indicator light lights up yellow or red over a large measuring range on
the wall.
Many metal objects
spaced closely together
Building materials con-
taining metal or reinfor-
cing steel in concrete
Solid metal objects on
the back of the wall
Auto-calibration not suc-
cessful
Metal object not found.
Metal object is too deep
or too small.
Error when searching for and indicating live cables
Cause
Indicator light flashes red over a large measuring range on the wall.
Insufficient earthing of
the wall
Live cable not found.
No/unusual voltage in the
cable
Bosch Power Tools
Corrective measures
Allow the measuring tool to reach the correct
temperature.
Manually recalibrate the measuring tool.
Be sure to listen to the pitch of the audio signal
in order to distinguish between individual metal
objects. Metal objects spaced too closely to-
gether cannot be detected separately.
In the presence of metallic building materials
(e.g. foil-laminated insulation materials, heat
conduction plates), reliable detection is not pos-
sible.
In the presence of solid metal objects (e.g. radi-
ators), reliable detection is not possible.
Manually recalibrate the measuring tool.
The detection depth depends on the building
material and on the object and may be less than
the maximum detection depth.
Corrective measures
Touch the wall with your free hand at a distance
of 20−30 cm from the measuring tool in order to
earth the wall.
Apply voltage to the cable, e.g. by turning on the
corresponding light switches. It is not possible
to reliably detect multi-phase electricity cables
English | 25