Making The Electrical Connection; Connection Diagrams - Festo SPAW B2R Mode D'emploi

Capteur de pression
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6. Commissioning, operation
6.1 Making the mechanical connection
The sealing faces at the instrument always have to be clean.
Only ever screw in, or unscrew, the instrument via the spanner flats. Never use the case as a working surface.
The correct torque depends on the dimensions of the pressure connection and the gasket used (form/material).
EN
When screwing in, do not cross the threads.
Seal
Correct sealing of the process connections at the sealing face must be made using suitable seals.

6.2 Making the electrical connection

The instrument must be earthed via the process connection.
The power supply for the pressure sensor must be made via an energy-limited electrical circuit in accordance with
section 9.3 of UL/EN/IEC 61010-1 or an LPS to UL/EN/IEC 60950-1 or class 2 in accordance with UL1310/UL1585
(NEC or CEC). The power supply must be suitable for operation above 2,000 m should the pressure sensor be
used at this altitude.
Long signal cables reduce the immunity to interference. Make sure that the length of the signal cable is always
shorter than 30 m. In this way you can avoid non−operate currents caused by electromagnetic interference.
For cable outlets, make sure that no moisture enters at the cable end.

Connection diagrams

Electrical connection
Description
Circular connector M12 x 1; 4-pin
Circular connector M12 x 1; 5-pin
12
OI_14070935_SPAW_GB_D_F_E.indd 12
Assignment
U
= 1
B
0V = 3
SP1 = 4
SP2 = 2
U
= 1
B
0V = 3
A
= 5
Out
SP1 = 4
SP2 = 2
Pressure sensor SPAW
05.08.2013 11:02:26