Design And Function - Festo SPAW B2R Mode D'emploi

Capteur de pression
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3. Specifications / 4. Design and function
Specifications
Electrical connections
EN
Electrical safety
Materials, wetted parts
Materials, non-wetted parts
Approvals
CE conformity

4. Design and function

4.1 Description
By means of a sensor element and by supplying power, the prevailing pressure is converted into a switching signal or
an amplified standardised electrical signal via the deformation of a diaphragm. This electrical signal varies in proportion
to the pressure and can be evaluated accordingly.
10
OI_14070935_SPAW_GB_D_F_E.indd 10
SPAW
Circular connector M12 x 1, 4-pin
Circular connector M12 x 1, 5-pin, only for version with two switching outputs and analogue
signal
Short-circuit resistance exists for analog- and switching outputs
Reverse polarity protection: U
vs. 0V
B
Insulation voltage: DC 500 V
Overvoltage protection: DC 40 V
Process connection: Stainless steel 316L
Pressure sensor ≤ 10 bar: Stainless steel 316L
Pressure sensor > 10 bar: Stainless steel 13-8 PH
Case: Stainless steel 304
Keyboard TPE-E
Display window: PC
Display head: PC+ABS-Blend
cULus, RCM Mark
per EU EMC directive
Pressure sensor SPAW
05.08.2013 11:02:26

Publicité

Table des Matières
loading

Table des Matières