Télécharger Imprimer la page

steute BZ 16 Instructions De Montage page 15

Publicité

BZ 16
//
Montage- und Anschlussanleitung / Sicherheitssensor
Mounting and wiring instructions / Safety sensor
Instructions de montage et de câblage / Capteur de sécurité
Istruzioni di montaggio e collegamento / Sensore di sicurezza
Instruções de montagem e instalação / Sensor de segurança
Инструкция по монтажу и подключению / Датчик безопасности
English
Safety-relevant data
EN ISO 13849-1:2008-12 PL e
DC
96%
avg
Category
3
B
20 million **
10d
T
max. 20 years
M
MTTF
100 years
d
DIN EN 62061
SIL CL 3
PFH
≥ 4.29 x 10
d
Requirement rates n
op
h
8 h/day
op
d
220 days/year
op
t
20 s/cycle
cycle
I
/U
140 mA/24 VDC ±15% (reverse voltage
e
e
protected)
Residual current I
≤ 70 mA
0
Short-circuit protection
U
0.25 A (slow blow)
e
Output contacts
2 enabling paths (2 NC or 1 NO/1 NC)
1 signalling contact (1 NC)
Switching voltage
max. 30 VAC/DC
Conditional short-
circuit current
100 A
Short-circuit protection 4 A (gG/gN) incoming series-connected
Utilisation category
of output contacts
AC-15; DC-13
of signalling contact
AC-12; DC-12
I
/U
e
e
of output contacts
max. 3 A/24 VAC/DC, min. 10 mA/5 VAC/DC
of signalling contact
max. 1 A/24 VAC/DC, min. 100 µA/100 mVDC
U
250 VAC
i
U
1.5 kV
imp
Voltage drop
< 0,6 V
Overvoltage category
III
Switching frequency
max. 1 Hz
Attendance delay t
< 300 ms
v
Risk time
max. 165 ms
Degree of pollution
3
Degree of protection
IP67 to IEC/EN 60529
Ambient temperature
0°C ... +55°C
Storage and transport
temperature
-20°C ... +70°C
Mechanical life
50 million operations
Output contacts
AgSnO self-cleaning, positive-guided
Signalling contact
AgNi, gold-plated
Output contact
resistance
100 mΩ in new condition
Signalling contact
resistance
max. 30 mΩ
Cable entry
3 x M20 x 1.5
Connection
wiring compartment with socket screw
clamps 8-pole
1/h
-8
Cable cross section
min. 0.14 mm² / AWG 28
max. 1.5 mm² / AWG 16
Ô
Designation
* Minimum distance 2 mm for approach from side.
** The safety-related data are based on a load of 24 V / 0.1 A / DC-1 for
the enabling paths. With higher load currents for the enabling paths
(see diagram and other requirement rates n
data vary from the given data and can be provided on request.
Français
Données techniques
Normes appliquées
EN 61000-6-1, -2, -3, -4; EN 60947-5-2;
EN 60947-5-3; EN ISO 14119; EN 60204-1;
EN ISO 13849-1; DIN EN 62061; 2004/108/EG
Type de capteur
type de construction 4 dispositif de
verrouillage
Niveau de codage
codage faible
Boîtier
thermoplastique renforcé de fibres de verre,
auto-extinguible
Object défini
actionneur BZ 16-B1 avec codification basse
code-article 1165032
Couples de serrage
vis de fixation pour boîtier: max. 2 Nm
vis de couvercle: max. 1,5 Nm
vis de fixation pour actionneur: max. 2 Nm
Distances de
commutation*
s
n
s
ao
s
ar
Hystérésis
env. 6 mm
Désalignement latéral ≤ 3 mm
Répétabilité
< 1 mm
Données relatives à la sécurité
EN ISO 13849-1:2008-12 PL e
DC
96 %
avg
Catégorie
3
B
20 millions **
10d
T
max. 20 ans
M
MTTF
100 ans
d
DIN EN 62061
SIL CL 3
PFH
≥4,29 x 10
d
Exigences n
op
h
8 h/jour
op
d
220 jours/an
op
t
20 s/cycle
cycle
I
/U
140 mA/24 VDC ±15 % (protegé contre les
e
e
inversions de polarité)
Courant résiduel I
≤ 70 mA
0
Protection contre les
courts-circuits U
0,25 A (lent)
e
15 / 24
) the safety-related
op
=
12 mm distance de détection assignée,
10 mm par montage affleurant
=
10 mm distance sûre de détection,
8 mm par montage affleurant
=
25 mm distance sûre de déconnexion
1/h
-8

Publicité

loading