Télécharger Imprimer la page

Vollrath SLM250/S Manuel D'utilisation page 5

Trancheurs électriques pour service moyen

Publicité

Les langues disponibles

Les langues disponibles

CLEAN AND SANITIZE THE SLICER (CONTINUED)
Clean the Slicer
NOTICE: Do not clean the slicer with abrasive materials or
scratching cleansers. These can damage the finish. Clean
the slicer with only water, a mild detergent and sanitizing
solution.
NOTICE: Hand-wash only.
NOTICE: Do NOT soak the sharpening assembly.
NOTICE: Do NOT wash the sharpening stones. Wet stones will not
properly sharpen the blade and will need to be replaced.
1. Wash the removable parts in a clean basin filled with a solution of
clean warm water and mild detergent.
2. Rinse the parts with clean warm water.
3. Use a soft cloth, clean warm water, and a mild detergent to clean the
non-removable parts of the slicer.
• The front and back sides of the blade. Start at the center of blade
and wipe toward the edge.
40950
• Blade guard and back of blade. Carefully wipe the back of the blade
and inside edge of the guard.
• Gauge plate. Start at the blade and wipe outward.
4. Body of the slicer.
5. Rinse the non-removable parts of the slicer with clean warm water.
Medium-Duty Electric Slicers Operator's Manual
Sanitize the Slicer
NOTICE: The sanitizer concentration shall comply with Section
NOTICE: If a chemical sanitizer other than chlorine, iodine or
1. Wash your hands.
2. Soak the removable parts in a clean basin, in a solution of clean
warm water and correctly-diluted sanitizing solution.
NOTICE: Do NOT soak the sharpener assembly. Wet stones will
3. Remove the parts from the basin and allow them to air dry. Do not
rinse or wipe the sanitizer off of the parts.
4. Moisten a soft clean cloth with correctly-diluted sanitizing solution.
40951
5. Use the cloth to sanitize the non-removable parts and body of the
slicer. See Step 3 under "Clean the Slicer." Do not rinse or wipe the
sanitizer off of the parts.
Reassemble the Slicer
1. Install the slice guard.
2. Install the blade cover knob and secure the blade cover. Position the
cover so the blade knob is clear of the carriage tray.
3. Install the carriage tray and tighten the carriage release knob until it
will no longer turn.
NOTICE: Tighten the carriage release knob until it will no longer
4. Install the product grip handle.
5. Install the blade sharpening assembly.
6. Tighten the blade sharpener locking knob.
Inspect the Slicer
• Inspect the slicer for correct assembly.
• Confirm the seal is in place and in good condition.
• Verify the carriage release knob is fully tight and the carriage tray
does not wobble.
• Verify the slicer is in good working condition.
• Do not use the slicer if it is not in good working condition. Contact
an authorized Vollrath service agency to service the slicer.
4-501.114, Manual and Mechanical Warewashing
Equipment, Chemical Sanitization – Temperature, pH,
Concentration, and Hardness of the FDA Food Code.
quaternary ammonium is used, it shall be applied in
accordance with the EPA registered label use instruction.
not properly sharpen the blade and will need to be
replaced.
40950
turn. Under-tightening could cause the carriage to wiggle
and damage the gauge plate or body of the slicer.
40951
5

Publicité

loading

Ce manuel est également adapté pour:

Slm300p/s4095040951