Further Information - Nice Mhousekit Cl2Sl Instructions Et Avertissements Pour L'installation Et L'utilisation

Table des Matières
Les langues disponibles

Les langues disponibles

––– STEP 9 –––
9.1 - ADVANCED SETTINGS
9.1.1 - Parameter settings via radio transmitter
The radio transmitter can be used to set a number of control unit operat-
ing parameters: there are eight parameters.
1) Pause time: duration for which the leaves remain open (in the case of
automatic closure).
2) Pedestrian opening: pedestrian opening mode of the leaves.
3) Motor force: maximum force above which the control unit detects an
obstacle, and reverses the movement.
4) "OPEN" function: sequence of movements associated to each "OPEN"
command.
Parameters
NO.
Pause Time
1
2
3
4
Pedestrian opening
1
2
3
4
Motor force
1
2
3
4
"OPEN" function
1
2
3
4
(*)
Original factory value
Parameters
No.
Open input configu-
1
ration on the control
2
unit
Flash configuration
1
2
3
Motor 1 and motor
1
2 discharge in clo-
2
sure
3
4
5
6
7
8
Motor 1 and motor
1
2 discharge in
2
opening
3
4
5
6
7
8
(*)
Original factory value
12 – English

FURTHER INFORMATION

Value
10s
20s (*)
40s
80s
Opening of 1 leaf to mid-travel
Total opening of 1 leaf (*)
Partial opening of 2 leafs to 1/4 of travel
Partial opening of 2 leafs to mid-travel
Low
Medium low (*)
Medium high
High
"Open", "Stop", "Close", "Stop"
"Open", "Stop", "Close", "Open" (*)
"Open", "Close", "Open", "Close"
Opening only
Value
Open (*)
Pedestrian opening
No discharge (*)
0.1 s (Minimum)
Gate open indicator
No discharge (*)
0.1 s (Minimum)
0.2s
0.3s
0.4 s (Medium)
0.5s
0.6s
0.7 s (Maximum)
No discharge (*)
0.1 s (Minimum)
0.2s
0.3s
0.4 s (Medium)
0.5s
0.6s
0.7 s (Maximum)
5) Discharging motor 1 when closing: adjusts the length of the "brief
reverse" of the motor after execution of the Close manoeuvre, in order
to reduce the final residual force.
6) Discharging motor 1 when opening: adjusts the length of the "brief
reverse" of the motor after execution of the opening manoeuvre, in
order to reduce the final residual force.
7) Discharging motor 2 when closing: adjusts the length of the "brief
reverse" of the motor after execution of the Close manoeuvre, in order
to reduce the final residual force.
8) Discharging motor 2 when opening: adjusts the length of the "brief
reverse" of the motor after execution of the opening manoeuvre, in
order to reduce the final residual force.
TABLE 3
Action: operation to be performed at point 3 of the settings
phase
Press T1 once
Press T1 twice
Press T1 three times
Press T1 four times
Press T2 once
Press T2 twice
Press T2 three times
Press T2 four times
Press T3 once
Press T3 twice
Press T3 three times
Press T3 four times
Press T4 once
Press T4 twice
Press T4 three times
Press T4 four times
TABLE 4
Actions to be performed
Press T1 once
Press T1 twice
Press T2 once
Press T2 twice
Press T2 three times
Press T3 once
Press T3 twice
Press T3 three times
Press T3 four times
Press T3 five times
Press T3 six times
Press T3 seven times
Press T3 eight times
Press T4 once
Press T4 twice
Press T4 three times
Press T4 four times
Press T4 five times
Press T4 six times
Press T4 seven times
Press T4 eight times