Festo EGSL Notice D'utilisation page 25

Mini-chariot
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

EGSL
Installing the effective load
Note
If the steel slide becomes bent against a
buckled effective load, the service life of the
guide will be reduced.
• Make sure that the mounting surface of
the effective load is even to within
t ≤ 0.05 mm.
Place the effective load so that the pull-out torque from the force
(parallel to the axis of motion) and lever arm remains low.
Check the necessity of adapter plates.
Connection of the EGSL to
Festo handling components is made
possible through adapter plates
(è chapter 10 "Accessories").
Fasten the effective load to the slide
unit with screws (A) and, if necessary,
with centring elements (B).
The screw-in depth must be less
than the threaded holes.
EGSL-...
Screw
Centring sleeve
Min. screw-in depth
– Guide rail
– Yoke plate
Festo EGSL 1602b English
35
(A)
M4
(B)
[mm]
7x3
(ZBH-7)
[mm]
3.6
[mm]
4.8
Fig. 5
(A)
(B)
Fig. 6
45
55
M5
M5
7x3
7x3
(ZBH-7)
(ZBH-7)
4.5
4.5
6
6
75
M6
9x4
(ZBH-9)
5.4
7.2
25