2.2
GeNeRAL INStRuCtIoNS
ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT,
PROVIDE ADEQUATE CLEARANCE FOR SERVICING AND OPERATING THE APPLIANCE.
OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48" FROM THE
SURFACES AROUND AND ESPECIALLY ABOVE THE APPLIANCE CAN BECOME HOT. AVOID CONTACT
HIGH PRESSURE WILL DAMAGE VALVE. DISCONNECT GAS SUPPLY PIPING BEFORE PRESSURE TESTING GAS
LINE AT TEST PRESSURES ABOVE 1/2 PSIG. CLOSE THE MANUAL SHUT-OFF VALVE BEFORE PRESSURE
TESTING GAS LINE AT TEST PRESSURES EQUAL TO OR LESS THAN 1/2 PSIG.
USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH THIS APPLIANCE.
USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS COMPONENTS, VENTING
COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL VOID THE WARRANTY AND CERTIFICATION.
DO NOT USE A BLOWER INSERT, HEAT EXCHANGER INSERT OR ANY OTHER ACCESSORY NOT APPROVED FOR USE
Thoroughly clean the chimney, flue and existing appliance
before installing the new appliance into it. Do not burn solid
fuels in any appliance that is equipped with this gas log set.
The installation of this appliance must conform with
local codes or in the absence of local codes, it must
conform to ANSI Z.223.1/NFPA 54 or the CAN/CGA B149.
The installation and the provisions for combustion and
ventilation air must conform with the National Fuel Gas
Code, ANSI Z223.1/NFPA 54, or the CSA B149.1, Natural
Gas and Propane Installation Code. The installation of
appliances designed for manufactured home (U.S. only) or mobile home installation must conform with the
Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and
Safety Standard, Title 24 CFR, Part 3280, in the United States, or when such a standard is not applicable, ANSI/
NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard.
Do not operate appliance in the presence of gasoline or other flammable liquids and vapours. Keep area
clear of other combustible materials. The appliance and its shut off must be disconnected from the gas
supply piping system before any pressure testing of the system is done.
Installation practices vary from region to region and it is important to know the specifics that apply to your
area,
For example: in Massachusetts State:
This product must be installed by a licensed plumber or gas fitter when installed within the
commonwealth of Massachusetts.
The appliance damper must be removed or welded in the open position prior to installation of an
appliance insert or gas log.
The appliance off valve must be a "T" handle gas cock.
The flexible connector must not be longer than 36" (914.4mm).
The appliance is not approved for installation in a bedroom or bathroom unless the appliance is a
direct vent sealed combustion product.
A carbon monoxide detector is required in all rooms containing gas fired appliances.
No external electricity (110 volts or 24 volts) is required for the gas system operation.
!
WITH THE GLASS DOOR OPENED OR REMOVED.
PROVIDE ADEQUATE VENTILATION.
NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE.
FRONT FACE OF THE UNIT.
WHEN THE APPLIANCE IS OPERATING.
FIRE RISK. EXPLOSION HAZARD.
WITH THIS APPLIANCE
WARNING
www.n certi ed.org
We suggest that our gas
hearth products be installed
and serviced by professionals
who are certi ed in the U.S.
by the National Fireplace
Institute ® (NFI) as NFI Gas
Specialists
W415-1101 / D / 08.28.18
5