Circuit Diagrams; Connection Terminals; Inputs And Outputs - DOLD SAFEMASTER W UH 6900 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Circuit Diagrams

13 23 33
O4
S11
S22 S24 S13 F0 F1 F2 F3
A1
S11
S12 S14
A2
IIR
+
S12
A1+
S13
A2
S14
13 23 33
S22
S24
S31
K1
S32
S33
S34
S42
Y1
Y2
K2
F0
F1
F2
F3
F4
BNC
14 24 34
F5
F6
F7
IIR
Y2
Y1
S42
OIR
S31 S32 S34 S33 F4 F5 F6 F7
14
14
24
34
O0

Connection Terminals

Terminal designation
A1+
A2
48/58
S11, S31
S13, S33
S12, S14
S22, S24
S32, S34
S42
Y1/Y2
13/14
23/24 or
21/22
33/34
IIR
OIR
Q25
F0 to F7
O0 to O7
A3+
O5 O6 O7
USB
A3
48
+
A3+
A3+ A3+
A3+
O0
O1 O2
O3
A3+
A3+ A3+ A3+
O4
O5 O6 O7
A1+
A1+
A1+
A1+
48
58
OIR
Q25
Q25
58
SMA
M11753
O1 O2 O3
Signal description
DC 24 V supply voltage for radio
controlled safety module
Common earth
Non-safety DC 24 V semiconductor
outputs: State of radio controlled
safety module
Test outputs for short circuit detec-
tion of the safety inputs Sx2
Test outputs for short circuit detec-
tion of the safety inputs Sx4
Inputs of the
two-channel safety input 1
Inputs of the
two-channel safety input 2
Inputs of the
two-channel safety input 3
Input for hard-wired start button
Input for feedback loop of external
contact reinforcement
1
safety output, safety NO contact
st
2
nd
safety output, safety NO contact
monitoring output (NC contact)
3
safety output, safety NO contact
rd
Input for enabling the received start
signal
Output with image of sent start
signal
Output for input signal quality
< -80 dBm
Non-safety function inputs
Non-safety DC 24 V function outputs
DC 24 V power supply of the
function outputs O0 to O7
13 21 33
O4
S11
S22 S24 S13 F0 F1 F2 F3
A1
S11
S12 S14
A2
IIR
+
S12
A1+
S13
A2
S14
13 33 21
S22
S24
S31
K1
S32
S33
S34
S42
Y1
Y2
K2
F0
F1
F2
F3
F4
BNC
14 34 22
F5
F6
F7
IIR
Y2
Y1
S42
OIR
S31 S32 S34 S33 F4 F5 F6 F7
14
14 22 34
O0

Inputs and Outputs

Inputs
- 3 two-channel safety inputs DC 24 V
- 1 DC 24 V input for start button
- 1 feedback circuit to monitor external relays
- 1 DC 24 V input that can be used as start signal in addition to the start
signal received via radio
- 8 non-safety-relevant DC 24 V functional inputs, the status of which is
sent to the opposite side
Outputs
- 3 safety-relevant NO contacts or 2 safety-relevant NO contacts
+ 1 NC contact
(can only be used as an indicator contact)
- 1 DC 24 V semiconductor output that reproduces the start signal sent
via radio as an additional start signal for the release of the safety relay
on the opposite side
- 8 non-safety-relevant DC 24 V semiconductor outputs that are controlled
by the opposite side
- 2 DC 24 V semiconductor outputs to display the status of the radio-
controlled safety module
- 1 non-safety-relevant DC 24 V semiconductor output to indicate poor or
missing radio control
16
O5 O6 O7
USB
A3
48
+
A3+
A3+ A3+
A3+
O0
O1 O2
O3
A3+
A3+ A3+ A3+
O4
O5 O6 O7
A1+
A1+
A1+
A1+
48
58
OIR
Q25
Q25
58
SMA
M11754
O1 O2 O3
UH 6900 / 01.09.17 en / 891