Design and Function

Solenoid locking units prevent opening of separating guards and keep
them closed as long as their is a risk of injury in the secured plant.
Attention!
!
Hazards must be ruled out before a key can be removed and
the movable part of the guard can then be opened!
The solenoid locking unit is to be integrated into a system and connected
with a control unit so that the hazardous machine can run only when the
guard is locked and closed.
An access can only be opened after a release signal was sent by the
machine control to the ZRH01A solenoid locking unit. The actuator can
only be removed from actuator module A and the access opened after
removing the key from key module 01. Key operation is forced. Key entry
ins blocked when the door is open. The key can be entered again after
the access was closed again. Only after entering the key is the solenoid
locking activated again and the machine can be restarted.
Key and magnet position are monitored by separate contacts.
ZRH01A is usually used in the system in connection with additional
STS units and SAFEMASTER products (e.g. release by speed monitor
UH 5947, standstill monitor LH 5946 or speed/standstill monitor BH 5932).
The key with forced removal can be used as protection against lock-in.

Indication

LED red:
LED yellow/green:
Magnet energized
Separately controllable

Circuit Diagrams

3
14
2
11
12
1
6
22
4
21
24
5
20
32
31
19
11
52
10
51
54
9
8
42
41
7
17
62
61
18
16
15
red
24
yellow
23
22
green
21
12
M11407_b
Fig. 1:
Solenoid locking activated:
Magnet locked, 1st key
removed, actuator and
2nd key inserted,
Door closed
3
14
2
11
12
1
6
22
4
21
24
5
20
32
31
19
11
52
10
51
54
9
8
42
41
7
17
62
61
18
16
15
red
24
yellow
23
22
green
21
12
M11413_b
Fig. 3:
Solenoid locking deactivated:
Magnet released,
1st key inserted,
Actuator removed,
Door open,
optionally 2nd key removed
20
SAFEMASTER STS-ZRH01A, ZRH01BM / 05.12.19 en / 166A
3
14
2
11
12
1
6
22
4
21
24
5
20
32
31
19
11
52
10
51
54
9
8
42
41
7
17
62
61
18
16
15
red
24
yellow
23
22
green
21
12
M11410_b
Fig. 2:
Solenoid locking deactivated:
Magnet released, optionally 1st
key insetred, actuator and key
inserted,
Door closed
ZRH01A, ZRH01BM
Mechanical switch
positions
Circuit diagram
3
2
3
1
6
4
6
5
19
20
11
9
11
10
7
8
17
18
De-energized
on trip
15
16
Energized on
trip
15
16
closed
open
The state shown in Figure 3 does
not depend on the control signal of
the magnet.
If the control signal is applied and
the actuator inserted the solenoid
locking changes to the state of
Figure 2.
If no signal is applied and the
solenoid locking is inserted the
solenoid locking changes to the state
of Figure 1