Function Diagram; Circuit Diagrams; Approvals And Markings; Applications - DOLD SAFEMASTER BN 5930.48 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Safety Technique
SAFEMASTER
Emergency Stop Module
BN 5930.48

Function Diagram

Circuit Diagram
A1
T11 T12 T12 T22 13 23 33 41
(+)
A1(+) PE(-)
13 23 33
41
T11
T12
K1
T12
T22
K2
T33
T34
K3
X1
X2
A2(-)
14 24 34
42
PE
T33 T34
X1 X2 14 24 34 42
(-)
M7398_b
All technical data in this list relate to the state at the moment of edition. We reserve the right for
technical improvements and changes at any time.
A2
(-)
• Same as BN 5983, but with other terminal designation
(see circuit diagram)
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
• Output: 3 NO, 1 NC contacts for AC 400 V
• 1-channel or 2-channel circuit
• LED displays for channel 1, 2 and mains
• Feedback circuit X1 - X2 for monitoring external contactors
• Removable terminal strips
• Width 100 mm

Approvals and Markings

Applications

Protection of persons and machines
• Emergency stop circuits on machines
• Monitoring safety gates

Notes

The PE terminal permits operation of the device in IT systems with insulation
monitoring and also serves as a reference point for testing the control voltage.
One or more extension modules BN 3081 or external contactors with
positively-driven contacts may be used to multiply the number of contacts
of the emergency-stop module BN 5930.

Connection Terminals

Terminal designation
A1 (+)
A2 (-)
T12, T22, X1, X2
T11, PE(-), T34
13, 14, 23, 24, 33, 34
41, 42
13
Signal description
+ / L
- / N
Inputs
Outputs
Forcibly guided NO contacts for
release circuit
Forcibly guided indicator output
BN 5930.48 / 22.01.19 en / 106A