Accessories

Here is a list with typical accessories. In order to get a
complete overview of all available accessories, please
contact the manufacturer.
• FW200 : heating system controls with conduit
interface full text display for controlling a heating
system with mixed or unmixed heating zones.
• FB100 :room sensor that displays device and system
information and allows changing the settings shown.
• IPM2 :
to control the components of a
zone module
heating system equipped with the FW200 controller.
• ISM2 :
solar module to
solar thermal system that are part of a central heating
system equipped with the FW200 controller.
2.6

Technical specifications

2.6.1

General

Designation

Dimensions

Weight (without packaging)
Rated voltage ICM
Frequency
Max. on-site circuit breaker
Power draw ICM
Rated voltage BUS
Internal appliance fuse,
heating pump output
Measuring range, supply
temperature sensor
Measuring range, outdoor
temperature sensor
Permissible ambient
temperature ICM
Permissible ambient
temperature, supply
temperature sensor
Permissible ambient
temperature outdoor
temperature sensor
Maximum cable length,
2-wire BUS connections
Maximum lead lengths,
sensor leads
NEMA definition
Table 1
General
control the components of a
Unit
(
fig. 2)
lb (kg)
1.76 (0.8)
VAC (V)
120
Hz
60
Amp
15
W
5
DC ... V
15
Amp
5 AF, ceramic,
filled with sand
° F
32 ... 212
( °C)
(0 ... 100)
° F
– 40 ... 122
( °C)
( – 40 ... 50)
° F
32 ... 122
( °C)
(0 ... 50)
° F
32 ... 212
( °C)
(0 ... 100)
° F
– 58 ... 212
( °C)
( – 50 ... 100)
ft (m)
(
table 6,
page 12)
ft (m)
(
table 7,
page 12)
Type 2
Details about the ICM module | 5
2.6.2
Dimensions
2-1/2" (62mm)
2-1/2" (62mm)
9-1/4" (235mm)
6 720 616 690-03.1TD
Fig. 2
Dimensions
2.6.3

Power connection parameters

1)
Pos.
Interface
A
Input
Power supply from the
power line or from the
previous module ICM
B
Output Power supply for
additional ICM
C
Output Pump
D
Output Remote fault
indication
E
Input
Supply temperature
sensor
F
Input
Outdoor temperature
sensor
G
Input
External switching
contact
H
Input
Heating controls
(ON/OFF contact)
I
Input
Heating controls
(proportional
interface)
J
2-wire
To the heating
BUS
controller (FW200)
K
2-wire
From the previous ICM
BUS
module
L
2-wire
To the next ICM
BUS
module
M
2-wire
To the boiler
BUS
Table 2
Wiring interface
1) (
fig.
, page
)
6
10
120 V AC,
max. 10 Amp.
120 V AC,
max. 10 Amp.
120 V AC,
max. 250 W
Dry contact,
max. 120 V,
2 Amp.
NTC
(
table 3)
NTC
(
table 4)
Dry contact
24 V DC
0-10 V DC
6 720 643 835 (2011/06)