Service; General; Maintenance Diagram; Periodic Maintenance - Dibo 2D MPU-M Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6. Service

6.1. General

All maintenance activities must happen at an disconnected machine and hoses without pressure.
Checking the electric components can happen exclusively by an expert.
Exclusively accessories and replacement components which have been approved by the manufacturer can be
used.
Directly after the activities all securities- and protection parts must be assembled, before the machine is put in
functioning.
"a golden rule" that contributes to a perfectly working machine with few problems, is well the following:
A DAILY CONTROL AND CLEANING OF THE MACHINE FREQUENTLY DO WONDERS!
To be able to guarantee a perfectly working system, one has first necessary a reliable and technical well consid-
ered machine, which is then faced secondly at regular times with a thorough maintenance. Therefore the experi-
ence and the "know-how" of DiBO a technical good working machine is insured and large maintenance turns
can be carried out by experienced DiBO technicians by means of appointment or maintenance contract, we can
suppose in advance that it is satisfied to these two points.

6.2. Maintenance diagram

6.2.1 General
The user can carry out only those actions for which in this book authorisation are given. Each other act has
been prohibited!

6.2.2. Periodic maintenance

- Control of the electric cables, high and low pressure hoses and coupling
and control of the oil level:
- refreshing pump oil:
- Cleaning water filter:
- All following refreshments of pump oil:

6.2.3. Control oil level / refreshing of pump oil

Check for each use of the machine the oil by way off oil level glass or with the oil level bar. Oil must stand
right with the sign of the oil level bar, if the this case is not, oil tops up until the sign. If oil looks forward to
there milky, consult directly the DiBO technicians. To refresh oil, as follows work goes:
- Unbolt the drain plug below the pump.
- Unbolt the tap with the oil level bar.
- Catch all oil in a barge and remove oil.
- Force up the drain plug there and top up the oil in the breach to the upper part to the right level.
- Force up the tap with the oil level bar there.
- Recommended oil: 1.836.041

6.2.4. Control/refreshing oil level of pneumatic valve

Check the oil level regularly by means of the look glass at the top.
Oil has no lubrication function (=static function), therefore there is no wear possible!
Fill up is only needed when the oil level has been decreased!
Check the oil by way off oil level glass or with the oil level bar. Oil must stand in the middle of the sign of oil
level bar, if this is not the case, fill the oil until the middle of the look glass.
If oil looks forward to there milky, consult directly the DiBO technicians. To refresh oil, as follows work goes:
- Unbolt the tap at the top with oil level bar.
- Top up the oil to the upper side, to to the middle of oil level and force up the tap there.
- Recommended oil: 1.836.025 (+ - 0.6 litres hydraulic oil).
DiBO b.v. 58
after each use.
first 25 hours.
each 50 hours.
each 250 hours.