8.3
Generating set identification
The identification plate for the unit (example shown below) is affixed inside one of the skirts or on the chassis.
(C)
(B)
Serial numbers will be required when requesting troubleshooting advice or spare parts. For your records, please enter the unit and
engine serial numbers below.
Unit serial number:
....../.............. - ........................... - .........
8.4
Specifications
Model
Maximum power
Rated output
Acoustic pressure at 1 m
Acoustic measurement uncertainty
Engine type
Maintenance kit
Recommended fuel
Fuel tank capacity
Recommended oil
Oil sump capacity
Oil cut-out*
Direct current
Alternating current
Circuit breaker(s)**
Socket type
Battery
Dimensions l x w x h
Weight (without fuel)
o: standard
*Oil cut-out: If there is no oil in the engine sump or if the oil pressure is low, the oil cut-out mechanism automatically stops the engine to prevent any
damage. If this occurs, check the engine oil level and top it up if necessary before looking for any other cause of the problem.
**Circuit breaker: The generating set's electrical circuit is protected by one or more magnetothermal, differential or thermal cut-out switches. In the
event of an overload and/or short circuit, the supply of electrical energy may be cut. If necessary, replace the circuit breakers in the generating set
with circuit breakers with identical nominal ratings and specifications.
8.5
Recommended fuel quality
Using fuel which does not comply with the following specifications risks causing irreversible damage not covered under the
warranty:
-
Cleanliness and quality: ensure that the diesel used does not contain water, that it is new and clean (not out of date or
contaminated).
-
Specifications: ASTM D975 - 1D or 2D, EN590 or equivalent.
-
Outdoor temperature below 0°C: use a special fuel (for more information, please contact one of our agents).
However, it is strongly recommended that the same type of fuel is used throughout the complete service life of the unit. If the unit is
used infrequently (less than once a month), use new fuel with each use or add a stabilizing additive to the fuel tank.
1494_EN.docx
(G)
(D)
(E)
(H)
(F)
(I)
(A)
(M)
........................................
1x2P+T-230V-10/16A - 1x2P+T-230V-
(A):
Model
(B):
CE/EAC marking
(C):
Guaranteed acoustic
(J)
power level
(D):
Maximum power
(K)
(E):
Nominal power
(L)
(F):
Power factor
Engine manufacturer:(e.g.
Kohler)
DIESEL 10000 A XL
9000W
7200W
95 dB(A)
0,7 dB(A)
KD425-2
RKDS3
Diesel
35L
15W40
2,59 L
O
X
230V - 31,3A
O
O
89,5 x 57 x 77 cm
162 kg
X: not available
21/242
(G):
Ground
(H):
Current amperage
(I):
Current frequency
(J):
Current voltage
(K):
Protection rating
(L):
Reference standard
(M):
Serial number
Engine serial number: (e.g Kohler (SERIAL
NO. 4001200908))
......................................................
DIESEL 15000 TA XL
10000
8000
95 dB(A)
0,7 dB(A)
KD425-2
RKDS3
Diesel
35 L
15W40
2,59 L
O
X
400V - 11,5A
O
1x2P+T-230V-10/16A - 1x2P+T-230V-
O
89,5 x 57 x 77 cm
169kg
2020-04-25