Emptying The C/L Container; Cleaning The C/L Container - IDC MIKRO ic Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

H A N D L I N G T H E C O O L A N T / L U B R I C A N T ( C / L )
7.2

Emptying the C/L container

NOTE:
Possible damage to the drain cock!
▷ Move/carry the supply unit only by the han-
dles!
▷ Place the supply unit [1] with its rear side facing
frontward on a table.
Fig. 12
1 Supply unit
2 Drain cock
3 Disposal receptacle
▷ Position a disposal receptacle [3] below the
drain cock [2].
▷ If required, mount a hose to the drain cock and
conduct it into the disposal receptacle.
▷ Open the drain cock.
The C/L flows out of the C/L container into the
disposal receptacle.
When the C/L container is empty:
▷ Shut the drain cock again.
7.3
1
The filter and the C/L container may only be
cleaned with water.
▷ Do not use cleaning agents.
2
3
Fig. 13
▷ Unscrew and remove the four star-knob nuts [1]
on the top side of the supply unit.
▷ Remove the cover [2] with the drain pipe.
▷ Remove the filter bag and empty it.
▷ Clean the filter bag.
▷ Rinse and clean the C/L container.
Dispose of the C/L in accordance with the
applicable regulations and laws. Proper
disposal of the C/L must be documented.

Cleaning the C/L container

NOTE:
2.
2
E N
1
1.
43

Publicité

Table des Matières
loading

Produits Connexes pour IDC MIKRO ic

Ce manuel est également adapté pour:

179625

Table des Matières