Mount the desired number
of cover caps and/
or reductions to the unit
and cut them open at the
desired diameter (Ø80mm /
Ø125mm)
7.4 • Installing the roof outlet
Install a roof outlet (max 10 Pa pressure loss at 250m
a louvre (type pressure relief damper or wall louvre) with
a round connection Ø150mm as closely as possible (<2m) to the ventilation unit.
Connect the exhaust of the fan with the roof outlet through means of
an isolated flexible duct diameter 125/150mm.
10 6
5
Make sure that the
connections that are not used
are sealed off with a sealing
cap. Connect the ventilation
ducts to the reductions. Use
the supplied straps.
/h) or
3
6
Unscrew the fan casing's
cover plate. Make sure that
the power is switched off!
Connect the power supply
according to the electrical
scheme (section 8.1).
< 2 m