If the switch is not accessible after
installation (depending on the country) an
additional means of disconnection must
be provided for all poles.
• For extra safety it is advisable to protect
the appliance with a residual current
device (RCD). Please contact a qualified
electrician for advice.
When switched off there must be an all-
pole contact gap of at least 3 mm (0,11")
in the isolator switch (including switch,
fuses and relays).
WARNING! THIS APPLIANCE MUST
BE GROUNDED
The electrical safety of this appliance
can only be guaranteed when continuity
is complete between it and an effective
earthing
system,
with current local and national safety
regulations.
It is most important that this basic safety
requirement is present and regularly
tested and, where there is any doubt,
the electrical wiring in the home should
be inspected by a qualified electrician.
The manufacturer cannot be held liable
for the consequences of an inadequate
earthing system such as an electric
shock.
The manufacturer cannot be held
liable for damage which is the direct or
indirect result of incorrect installation or
connection.
WARNING!
which
complies
Electrical
Shock
Hazard
Disconnect power
before servicing.
Use
10
gauge
copper wire.
Electrically ground
cooktop.
Failure to follow
these instructions
can result in death,
fire, or electrical
shock.
Electrical Connection
The cooktop is equipped with a flexible
metal conduit encasing 3 wires ready for
connection to a grounded power supply.
Please note the nameplate label located
below the cooktop
1. Disconnect power.
2. Remove junction box cover if it is
present.
3. Connect the flexible cable conduit from
the cooktop to the junction box using a UL
listed or CSA approved conduit connector.
4.Tighten screws on conduit connector if
present.
5. See next page to complete installation
for your type of electrical connection.
UL listed or
CSA approved
conduit
connector
Please see Fig. 5:
208/240 V, 60 Hz, from 50 A fuse rating
to 35 A
Black wire: connect to L1 (hot)
Red wire: connect to L2 (hot)
Green/Yellow wire: connect to GND
(ground)
A dedicated line and junction box should
be used to connect the cooktop to a 35 A
circuit.
Nameplate
7