TermoSovrana DSA
the horizontal stretch must never exceed 2 m (UNI 10683-2005);
each bend of the flue gas channel slightly reduces the flue draught which must be compensated if necessary
by elevating it suitably;
The UNI 10683-2005 – ITALY regulation requires that under no circumstances must there be more than 2
bends or variations in direction including the intake into the flue.
If the user wishes to use the flue as a fireplace or open hearth, it is necessary to seal the hood below the entrance
point of the flue gas channel pos.A Picture 14.
If the flue is then too big (e.g. 30x40cm or 40x50cm), it is necessary to intubate it with a stainless steel tube with a
diameter of at least 200mm, pos.B, taking care to close the remaining spaces between the pipe itself and the flue
immediately under the chimney pot pos. C.
Picture 14
7094211 – EN
For any further clarifications, please contact your local dealer!
C - Plugging
B
A – Hermetic closure